1978-06-07 Septic System Design
Orono
>
Property Files
>
Street Address
>
C
>
Colin Drive
>
2165 Colin Drive - 03-117-23-21-0017
>
Septic
>
1978-06-07 Septic System Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 3:14:14 PM
Creation date
2/20/2025 2:24:15 PM
Metadata
Fields
Template:
x Address Old
House Number
2165
Street Name
Colin
Street Type
Drive
Address
2165 Colin Drive
PIN
0311723210017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c. If a starter ring is used, it shall be constructed of a 4,000 psi core <br />test concrete mix, cured to a seven-day strength before installation. <br />It shall extend at least one inch beyond the tank wall, inside and out. <br />A bottom shall be poured of concrete mix defined in Section (b) above. <br />It shall extend at least two inches above the starter ring and shall be <br />at least four inches thick. <br />d. If a precast bottom is used, it shall be made of a 4,000 psi core test <br />concrete mix, cured to a seven-day strength before installation. It <br />shall extent at least one inch beyond the tank wall, or be cast <br />integrally with the bottom section. <br />e. A sectional tank not having an integrally precast bottom shall have a <br />four -inch thick bottom poured within the tank wall. <br />5. Covers <br />a. Any tank cover not integrally cast with the tank shall be so installed <br />that the joint witn the tank sidewall is permanently sealed so as to be <br />watertight. <br />b. All covers shall be so designed and constructed as to withstand a <br />minimum of seven feet of saturated earth cover above the tank top. <br />F. Inlet and Outlet Device Materials <br />1. Inlet and outlet devices shall be sanitary tett), or baffles constructed of <br />acid resistant concrete, acid resistant fiberglass or plastic. <br />2. Sanitary tees shall be glued to the inlet or outlet pipes. Baffles shall be <br />integrally cast with :he tank, affixed with a permanent waterproof adhesive <br />or affixed w?th stainless steel connectors, top and bottom. <br />2. DESIGN <br />All tanks, regardless of material or method of construction, shall conform to <br />the followinq design criteria: <br />A. The 11QUI) DEPTH Of any septic tank or compartment thereof shall be not less <br />than 3U inches. A liquid depth greater than six and one-half feet shall not <br />be considered in determining tank capacity. <br />B. No tank or compartment thereof shall have an inside horizontal dimension less <br />than 24 inches. <br />C. Inlet and outlet connections of the tank thereof shall be submerged by <br />means of vented, sanitary tees of baffled. <br />0. The space in the tank between the liquid surface and the top of the inlet <br />and outlet baffles or sanitary tees shall oe not less than 20 percent of the <br />total required liquid capacity, except that in horizontal cylindrical tanks <br />this space shall be not less than 15 perctart of the total required liquid <br />capacity. <br />