My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1986-10-02 Plan Review
Orono
>
Property Files
>
Street Address
>
C
>
Colin Drive
>
2150 Colin Drive - 03-117-23-21-0015
>
Permits/Inspections
>
1986-10-02 Plan Review
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 10:33:12 AM
Creation date
2/20/2025 10:14:13 AM
Metadata
Fields
Template:
x Address Old
House Number
2150
Street Name
Colin
Street Type
Drive
Address
2150 Colin Drive
PIN
0311723210015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLAN REVIEW - 95 SOUTH BROWN ROAD <br />October 2, 1986 <br />Page 8 <br />81. Composition shingles shall have an underlay of not less than 15# <br />felt, applied as a base sheet. Sec. 3203-d-5-a. <br />82. Composition shingles shall be laid on slopes that are 4/12 or <br />greater. If less, installation approval must be granted by the <br />Building Official. Sec. 3203-g-2. <br />83. Roof valley flashing shall be provided of not less than #28 gals. <br />sheet gauge corrosion resistant metal and shall extend at least 8 <br />inches from the center line each way, and shall have a splash diverter <br />rib not less than 3/4" high at the flow line. Sec. 3203-d-5-b. <br />84. Enclosed attics and enclosed rafter spaces formed where ceilings <br />are applied direct to the underside of roof rafters shall have cross <br />ventilation for each separate space by ventilating openings protected <br />against the entrance of rain and snow. The area shall be not less n <br />1/150 of the area of the space ventilated. Except that the area may <br />be 1/300 roviri�2d at least 508 of the required ventilation area is <br />providPa .,y ventilators located in the upper portion of the space to <br />be v.,ntilated at least 3 feet above eave or cornice vents with the <br />ba ance of the required ventilation provided by eave or cornice vents <br />MECHANICAL SECTION <br />85. At least three feet clear space shall be provided in front of all <br />zone valves and controls, etc. for access and servicing. Sec. 7209 <br />SBC <br />86. Chimneys shall F!xtend at least 3 feet above the highest point <br />where they pass through the roof of a building and at least 2 feet <br />Iiigher than any portion of any building within 10 feet. Sec. 7403 SBC <br />87. All masonry chimneys to which heating boilers or furnaces are to <br />be connected shall be subject to and most successfully withstand a <br />smoke test before such connection is permitted. Sec. 7403 SBC <br />88. All chimneys shall have cleanouts and the cleanouts shall be <br />constructed so that they will remain tightly closed when not in use. <br />Sec. 7403 SBC <br />89. Masonry chimneys serving gas fired boilers, furnaces or other <br />heating devices, whether of the gas designed type or fired by gas <br />conversion burners, having an input not exceeding 400,000 BTU per <br />hour, rhali be lined continuously from the thimble to the top of the <br />chimney with an approved non-combustible, acid and corrosion resisting <br />liner of the same equivalent cross sectional area as the vent <br />connector. Sec. 7403 SBC <br />90. A condensation pocket shall be provided at the base of said liner <br />with provision for a drip, so arranged that excessive condensation of <br />combustion products may be disposed of. Sec. 7403 SBC <br />
The URL can be used to link to this page
Your browser does not support the video tag.