My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1986-01-23 Septic System Specifications
Orono
>
Property Files
>
Street Address
>
C
>
Chippewa Lane
>
4385 Chippewa Lane - 31-118-23-42-0017
>
Septic
>
1986-01-23 Septic System Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2025 9:06:54 AM
Creation date
2/13/2025 9:01:17 AM
Metadata
Fields
Template:
x Address Old
House Number
4385
Street Name
Chippewa
Street Type
Lane
Address
4385 Chippewa Lane
PIN
3111823420017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E. The inlet baffle or sanitary tee shall extend at least six inches but not <br />more than 20 percent of the total liquid depth below the liquid surface and <br />at least one Inch above the crown of the inlet sewer. <br />F. The outlet baffle or sanitary tee and the baffles or sanitary tees between <br />compartments shall extend below the liquid surface a distance equal to <br />40 percent of the liquid depth except that the penetration of the indicated <br />baffles or sanitary tees for horizontal cylindrical tanks shall be <br />35 percent of the total liquid depth. They also shall extend above the <br />liquid surface as required in 0. above. In no case shall they extend less <br />than six inches above the liquid surface. <br />G. There shall be at least one Inch between the underside of the top of the <br />tank and the highest point of the inlet and outlet devices. <br />H. The inlet invert shall be not less than three inches above the outlet <br />invert. <br />I. The Inlet and outlet shall be located opposite each other along the axis of <br />maximum dimension. The horizontal distr^ce between the nearest points of <br />the Inlet and outlet devices shall be a.. least four feet. <br />J. Sanitary tees shall be at least four inches in diameter. Inlet baffles <br />shall be no less than six inches or no Wore thin 12 inches meausred from the <br />end of the inlet pipe to the nearest point on the baffle. Outlet baftles <br />shall be six inches measured from beginning of the outlet pipe to the <br />nearest point on the baffle. <br />K. Access to the septic tank shall be as follows: <br />(1) There shall be one or more manholes, at least 20 inches least dimension, <br />and located within six feet of all walls of the tank. The manhole shall <br />extend through the cover to a point within 12 inches but no closer than <br />six inches below finished grade. The manhole cover shall be covered with <br />at least six inches of earth. <br />(2) There shall be inspection pipe of at least four inches diameter or a <br />manhole over both the inlet and o6' -et devices. The inspection pipe shall <br />extend through the cover and be capped flush or above finished grade. A <br />downward projection of the center line of the inspection pipe shall be <br />directly in line with the center line of the inlet or oitlet device. <br />L. Multiple Tanks <br />(1) Where more than one tank Is us•.d to obtair :he required liquid volume, the <br />tanks shall be connected in series. <br />(2) Each tank shall comply with all other r -o sions Of Section I.A. <br />(3) No more than four tanks In series can be us.w to obtain the required liquid <br />volume. <br />.a - <br />