My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1986-08-11 Mechanical Specifications
Orono
>
Property Files
>
Street Address
>
B
>
Bohns Point Road
>
1535 Bohns Point Road - PID: 08-117-23-44-0025 - New PID
>
1535 Bohns Point Rd - PID: 08-117-23-44-0023 - Old PID
>
Permits (2)
>
1986-08-11 Mechanical Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2024 2:02:05 PM
Creation date
8/28/2024 1:59:22 PM
Metadata
Fields
Template:
x Address Old
House Number
1535
Street Name
Bohns Point
Street Type
Road
Address
1535 Bohns Point Road
PIN
0811723440023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I-, <br />* <br />h <br />\^4 <br />* <br />'ftmu <br />3.02 <br />A. <br />3.03 <br />A. <br />B. <br />C. <br />3.04 <br />A. <br />3.05 <br />A. <br />4"' 9*7-1/2*4-1/2 <br />6"10*9*5* <br />8"11*9-1/2**5-1/2 <br />10" <br />’ HANGER <br />12* <br />AND SUPPORTS <br />10*6’. <br />Ductwork shall be substantially supported with hangers to <br />ceiling or otherwise, depending upon local conditions, placing <br />supports according to recommendations of SMACNA along entire <br />length of duct. All hangers shall be made of heavy 1" wide <br />strips riveted or bolted to sides of ducts. Upper ends of <br />hangers to be securely fastened to ceiling or masonry by <br />means of expanion bolts. No wood plug driven in masonry <br />will be permitted. Punching of holes in any way will not <br />be allowed. No nails, wires or cotter pins shall be run <br />through ducts. All necessary hangers, braces, tees, angles <br />and supports will be provide and secured in a satisfactory <br />manner. Vertical ductwork shall be supported at each floor. <br />BRACKETS, BRACES AND SUPPORTS <br />Furnish and install brackets, braces or reinforcing angles <br />as may be required in all partitions, not sufficient in them <br />selves to support wall mounted equipment included in this <br />specification. <br />No equipment shall be supported by the piping system itself. <br />All units shall be supported in a manner to allow service <br />without removing large piping segments or valves. Provide <br />structural members as required. <br />On brick, masonry block, hollow tile or concrete walls not <br />finished on opposite side of wall, use brass toggle bolts <br />or 3/8" brass bolts extending at least 3" into wall secured <br />in place by molten lead run in around the bolt and caulked. <br />EQUIPMENT SUPPORTS <br />Foundations, supports, anchors, concrete cover, anchor bolts, <br />sleeves, grouts, shims, etc., required for properly placing <br />mechanical equipment furnished under this contract shall <br />be provided by this Contractor, unless specifically stated <br />otherwise. <br />EXPANSION LOOPS, GUIDES AND ANCHORS <br />Piovide and install expanion loops, guides and anchors as <br />required, shown or specified to handle all thermal expansion <br />and contraction in piping systems. The loops shall be made <br />of dimensions shown or fabricated with long radius elbows <br />and piping of maximum lengths that space permits where dimen <br />sions are not given. Loops shall be installed with "cold <br />springs" so that loop in operation will have approximately <br />equal contraction and expansion from fabricated position. <br />15090-4
The URL can be used to link to this page
Your browser does not support the video tag.