Laserfiche WebLink
Zoning File #1696 <br />October 17, 1991 <br />Page 3 <br />The 23' X 35' addition consists of a full basement, first <br />floor (family room/bedroom), second level garage and third floor <br />master bedroom. Staff has questioned the applicant as to the <br />size of the footprint of the addition, noting that it is larger <br />than the existing principal structure and asked if certain <br />elements of structure could be reduced. Applicant advises that <br />the two-stall garage is needed and that the interior access <br />stairs at an 8' width is needed to serve both the lower levels <br />and upper level of the master bedroom. Review Exhibit I, the <br />elevations, profiles and floor plans. There is no feasible way <br />to connect a stairs access to the third level in the new addition <br />via the existing portion of the house. The only interior access <br />to lower levels and original house portion is via down staircase <br />(4* of additional width). The only access to upper level is via <br />up staircase (4* of additional width). If a total of 8' i^ <br />needed for stairs, then two-stall garage occupies 27' of width. <br />Note applicant proposes no change in the existing portion of the <br />residence• <br />The existing exterior access stairs shall be removed and <br />rebuilt in a safer manner, certainly with handrails meeting all <br />DBC standards. Mr. Ward advised that a policeman in making an <br />attempt to get down to their residence slipped and fell in icy <br />conditions during the winter. This is a continuous problem and <br />the main reason for the proposed interior access in the addition. <br />Applicant proposes three decks from the master bedroom <br />level. The deck facing the lake will be extended over the <br />existing roof requiring no additional approvals of hardcover or <br />setbacks. The deck to the west side results in 24 s.f. of <br />additional hardcover (8' x 3'). Deck to the north is proposed a <br />merely a 1-1/2' width. Applicant asks if the 1-1/2' deck would <br />be the same as a 1-1/2* overhang which is considered a non­ <br />encroachment into a setback area. The deck structure requires a <br />setback and would result in an additional setback variance of 1- <br />1/2' into the proposed 10* street setback. Note per hardcover <br />facts this was not included because it was pxaced over the paved <br />drive area. <br />Staff comments regarding existing and proposed hardcover <br />improvemerts also noting area and percentages of hardcover <br />resulting with these improvements. <br />A. Proposed addition. If interior access is desired <br />requiring the 8' of width to provi a staircase both <br />to an upper and lower level, then possibly the two- <br />stall garage could be reduced from 27' in width to 24* <br />resulting in the final footprint of 736 s.f, or 8.7% <br />(two-stall garage 24* x 23') as opposed to the proposed <br />805 s.f. at 9.5%. Applicant should be asked to <br />respond.