Laserfiche WebLink
City of Oroao Public Works Depafljaent <br />Project No. CMKX-93-0163 <br />January 28. 1994 <br />Fife 3 <br />B.2 Soil Borinc Investigntioa <br />Braun IntertK conlucted seven penetratkm test borings duriog Novembv and <br />Decenri>er, 1993. Please see Figure 3 in Appendix A for the fonner soil boring (ST-1 <br />through ST-7) locations. Three soil borings were conducted in the area of the fonner 3,000- <br />gallon unleaded gasoline UST basin and four were conducted in and around the area of the <br />fonner S60-gallon diesel fuel UST which was suspected ti) have leaked. Laboratory analysis <br />of soils collected from diese soil borings indicated the possiMe cofttamination of groundwater. <br />C.Scope of Work <br />Braun Intertec prc^>osa the following scope of work to address the petroleum contaminated <br />soil surrounding the former 3,(X)0-gallon unleaded gasoline and 560-galIon diesel USTs <br />described above, and to address the potential groundwater contamination which may be <br />present at this site: <br />Monitoring well permits will be t^tained prior to drilling aaivities. <br />•Drilling four soil borings, one approximately 20 feet south of the fonner 3,000-gallon <br />unleaded gasoline UST and three in the area of the 560-gallon diesel UST. The soil <br />borings would extend approximately seven feet below the water table (25 feet below <br />ground surface; groundwater was determined to be approximately 18 feet belo v ground <br />surface during the initial soil boring program). <br />Collecting soil samples at 2.5 foot vertical intervals using a split-spoon sampler. <br />Field-screening soil samples for the presence of organic vtq^ using a PID or HD. <br />Collecting a maximum of two soil samples from each boring for laboratory analysis. <br />Sod samples for laboratory analysis will be collected from the depth interval yielding <br />the highest PID reading and/or from the depth interval immediately above the apparent <br />water table. <br />Analyzing a minimum of one soil sample from the boring performed in the area of the <br />former 3,0(X)-galIon unleaded gasoline UST for benzene, ethyl benzene, toluene and <br />xylenes (BETX), methyl tertiary butyl ether (MTBE), gasoline range organics (GRO) <br />and percent total solids. For cost estimating purposes, it is assumed that only the <br />sample from the water table interface from this boring will be analyzed. <br />Analyzing a minimum of three soil samples from the borings performed in the area of <br />the former 560-gallor. UST for benzene, ethyl benzene, toluene and xylenes (BETX), <br />diesel range organics (DRO) and percent tot^ solids. For cost estimating purposes, it <br />is assumed that only the sample from the water table interface from each boring will be <br />analyzed.