The water tank shall have a capacity of 400 gallons. <br />100203.1 - TANK BUILD SPEC <br />The water tank shall be constructed of black polypropylene, poly-welded and tested inside and out. The tank manufacturer <br />shall define the floor, top, sides, ends, and baffles material thickness. The tank shall carry a lifetime warranty. <br />The transverse and longitudinal swash partitions shall be interlocked and welded to each other as well as to the walls of the <br />tank. The partitions shall be designed and equipped with vent holes to permit air and liquid movement between <br />compartments. The tank covers shall be welded on top and bottom, and the transverse partitions, providing rigidity during <br />fast fill operations. Drilled and tapped holes for lifting eyes shall be provided in the top area of the water tank. <br />The water tank manufacturer shall certify the capacity of the water tank prior to delivery of the apparatus. This capacity <br />shall be recorded on the manufacturer's data plate. <br />100205.1 - NFPA COMPLIANCE <br />The water tank construction shall conform to applicable NFPA standards. <br />100206.1 - WATER TANK SIGHT GAUGE <br />The water tank shall be equipped with translucent water level sight gauge in the rear wall of the tank. <br />100207.1 - FILL TOWER LOCATION <br />The tank fill tower shall be located in the driver's side rear corner of the water tank. <br />100209.1 - VENT AND OVERFLOW <br />The fill tower shall incorporate a vent and overflow system shall be designed into the water tank. The system shall include a <br />3" diameter pipe that functions both as an air vent while emptying the tank and as an overflow when filling the tank. The <br />overflow shall discharge excess water below the frame rails of the vehicle. <br />100215.1 - PUMP TO TANK CONNECTION <br />An 1-1/2" connection shall be provided on the water tank for connection of the discharge side of the pump to the tank for <br />filling purposes. The valves and hose required to complete this connection shall be supplied by the final assembler. <br />100216.1 - WATER TANK DRAIN PLUG <br />A 1.5" drain plug shall be installed in the bottom of the water tank under P/S wheel well for water tank draining and flush-out <br />of debris. <br />100227.1 - FOAM TANK SPECIFICATIONS <br />The Class A foam tank shall have a capacity of 10 gallons. <br />100232.1 - FOAM TANK AND VENTING PROVISIONS <br />The foam concentrate tank shall be provided with a fill pipe having a volume of not less than 2 percent of the total tank <br />volume. The filler opening shall be capped with a sealed air-tight threaded cover. The fill opening shall be designed to <br />incorporate a removable screen and shall be located so that foam concentrate from a five (5) gallon container can be <br />dumped into the tank. <br />The foam tank filler shall be equipped with a pressure/vacuum vent that enables the tank to compensate for changes in <br />pressure or vacuum when filling or withdrawing foam concentrate from the tank. The pressure/vacuum vent shall not allow <br />atmospheric air to enter the foam tank except during operation or to compensate for thermal fluctuations. The vent shall be <br />protected to prevent foam concentrate from escaping or directly contacting the vent at any time. The vent shall be of <br />sufficient size to prevent tank damage during filling or foam withdrawal. <br />A color coded label or visible permanent marking that reads "CLASS A -- FOAM TANK FILL" shall be placed at or near the <br />foam concentrate tank fill opening. An additional label shall be placed at or near any foam concentrate tank fill opening <br />stating the type of foam concentrate the system is designed to use. <br />Any restrictions on the types of foam concentrate that can be used with the system shall also be stated, along with a <br />warning message that states "WARNING: DO NOT MIX BRANDS AND TYPES OF FOAM." <br />100233.1 - FOAM SYSTEM PIPING <br />Skeeter Brush Trucks Page 10 07/21/2023
The URL can be used to link to this page
Your browser does not support the video tag.