Laserfiche WebLink
#2369 - Fiedler <br />May 14, 1998 <br />Page 2 <br />3. Requirements per Section 10.22 Subd 2 and 10.56 Subd. 16L: <br />Hardcover Limitation Existing Proposed Variance <br />75-250'zone = 25% 1180 sf (13.0%) 2391 sf (26.3%) 121 sf(1.3%) <br />(Area = 9,088 sf; 25% = 2,272 sO <br />250-500'zone = 30% 285 sf (17.9%) 564 sf (35.5%) 88 sf (5.5%) <br />(Area = 1,588 sf; 30% = 476 s.f.) <br />(Existing hardcover and zone split as calculated by staff) <br />4. Requirements per Section 10.03 Subd. 14C; <br />Lot Coverage Bv Structures Limitation: 15% of entire lot area = 0.15x10,676 sf= 1601 sf. <br />Existing Lot Coverage = 688+192 = 880 sf = 8.2% <br />Proposed Lot Coverage = 1320+660 = 1980 sf = 18.5%* <br />Variance = 379 s.f. (3.5%) <br />*21.2% if deck included; applicant indicates deck will be eliminated. <br />Discussion <br />Applicants purchased this property in 1991 and are requesting a number of variances to allow <br />removal of the existing residence and small shed, and replacement with a larger residence and <br />detached garage. The lot is only 50' x 213', or about 1/4 acre. The existing house and shed do not <br />meet required setbacks of the LR-1A district. Conceptual plans and elevation views for the new' <br />residence have been submitted. The footprint of the proposed house is about double that of the <br />existing house, and the new garage will be more than 3 times the size of the existing shed. <br />A portion of the new house and garage, and most of the proposed driveway, will be in the 250-500' <br />hardcover zone. The requested hardcover variances are relatively minor given the small lot size. <br />The lot coverage variance is significant. Recall that Section 10.03 Subd. 14C allows 1500 s.f. of <br />structures regardless of lot area. This lot could have as much as 1601 s.f of structure based on lot <br />size, but is proposing 1,980 s.f of structure (not including the deck), an excess of 379 s.f <br />The proposed side and side street setbacks of 10' become critical from a grading and drainage <br />standpoint due to site topography. A retaining wall located in the northerly alley right-of-way is <br />in disrepair. Plans should be submitted showing how this wall will be dealt with, as well as how <br />grades will change on the site to accomodate the proposed walkout, and how drainage will be <br />directed to avoid impacts to neighboring properties. <br />The proposed 5' side setback for the garage and 22' depth of garage leave a driveway apron within <br />the lot boundary of about 23', adequate for parking a vehicle within the lot boundaries. If the garage <br />is moved northward to meet the required 10' setback, this leaves an 18' apron, barely space enough