Laserfiche WebLink
1/1 Bonestroo <br />Rosene <br />^5 Anderlik & <br />Associates <br />Engineers & Architects <br />:-orcitroo Po\^nv AndvrUk i^nd Aiioci Inc /s A. j rcr ■? I't Acttor Ecju.U (Jpcortunity £mplc 'cr <br />Pnnctp-^ls Otto G Bnnestroo. PC • Joseph C Anderlik, PE • V.*rvin L Sorv.ilcV PC • <br />pichcifcl E Turner P». • Glenn R Cook PE • Robert G Scrun»(.nt ^E • Jerry A Bourdon. PE • <br />Robert W Pcsene PE ^nd Sui.rn M Eberlin, C PA Senior Con-,.ult.'nii <br />Ajsoc/4rft* Prin-i pt^li Ho*v *rd A S.snford. PE • Keith A Gordon. PF • Robert R Pfefferle, PE • <br />Rich;srd W Foster. PE • Oervid O LOSKOM. PE • Robert C A • Mtirk A H«<nson. PE • <br />Mich,^ei T ^sutmann PE • Ted K Field PE • Kenneth P Anderson. PE • Mt^rk R Poits, PE • <br />Sidney P Wili^mson. **E L S • Robert F Ko T^itn <br />Cffices St '■^uf Rochester. Wuim.ir ^ind St Cloud MM • Mii.v^uk-e VII <br />May II. 1998 <br />Mr. Michael P. GaflVon <br />Senior Planning tr^wrdinator <br />City of Grono <br />Post Offiee Bo.x 6(r <br />Crystal Bay. MX ‘55323 <br />1 <br />Rc;Barry Hapiund Subdivision <br />NJo I <br />Dear Mike: <br />We have reviewed the preliminary plat for the proposed two lot Haglund subdivision. The site is located west <br />of North Arm Lane and north of North Arm Drive in the northwest quarter of Section 6. We have the <br />following comments in regards to engineering matters. <br />1. Access: North Arm Lane provides ihe existing access to the site. The roadway is a publicly maintained <br />dead end pnva»e '••.leet, 18 lo 20 feet wide, approximately 1100 feet long and potentially serving 7 to 8 <br />prcpeftie.s. Tiic .‘southerly end of the roadway is paved from North Ann Drive to approximately 300 feet <br />noith. the remaining ; ‘ngth is gravel. The majority of North Arm Lane lies east of the subject property <br />wr.b.ut an exif’.ing r.gi •. ot-way that varies in width from 33 to 50 feet. The south end of North Arm Lane <br />ennoaches e-ibieily onto Lot 2, Block 1. North Arm Estates and southerly onto R.L.S. No. 924. North <br />Arm Lane shoulu be reconstructed to a minimum paved width of 28 feet to meet current City standards <br />for a private street serving 3 to iO units. A cul-ae-sac should be constructed at the north end of Lot 1 to <br />provide room for emergency vehicle turning movements. We recommend that the southerly end of North <br />Arm Lane be realigned so the roadway does not encroach on neighboring properties. The intersection of <br />North Arm Drive and North Arm Lane should be realigned to be as close to perpendicular as possible. <br />An additional 8.5 feet of right-of-way should be acquired along the east side of Lots 1 and 2. Right-of- <br />way should also be acquired to allow for cul-de-sac construction on the north end and the intersection <br />realignment on die so'jii' end. <ar.d spcciricatlcns for North Arm Uane improvements should be <br />piovided foi leview. <br />2. Gratli :g: A grading and erosion control plan for the entire site should be submitted for review. Erosion <br />co.U ’.o! measures sliould be in place prior to any grading, particularly along the east and north property <br />lines of Lc- i. Additional e. F.^ n control will be needed during construction of the house and septic <br />system. <br />3. Drainage: Tlie draft vereicn ot the City ’s’ Comprehensive Storm Water Management Plan (SWMP) shows <br />that the site drains eMierly to an existing wetland identified as NA-P2. The SWMP has classified NA-P2 <br />as a morteratply susceptible v''etland. Phosphorous loadings leaving the site should be limited to a <br />maximum of 0.28 pburid^acre/ycar. We also recommend that a ponding area be constructed to provide <br />water quality, rate* contrbi dnd nutrient rem.oval of storm water leaving the site. An existing depression <br />in the southeast comer of Lot I may provide a natural location for such a pond. A majority of the site <br />eui.-enfiy dmrii.s lo Mie depression and then easterly through an existing culvert under North Arm Lane. <br />A -Jiainavc u:ea mnp and ponding calculations should be provided with the final plan set. <br />2335 West Highway 36 - St. Paul, MN 55113 ■ 612-636-4600 - Fax: 612-636-1311