Laserfiche WebLink
r » <br />Zoning File #2355 <br />April 13,1998 <br />Page 3 <br />The current County right-of-way acquisition obviously has the greatest impact on the development <br />potential of the southeasterly 8 acres. Reducing it to 6 acres in a 5-acre zone and leaving Lot 1, <br />Block 3 without a second drainfield site, makes it impossible to meet City standards for creation of <br />two conforming lots from this portion of the property. The solution that staff has concluded is most <br />appropriate, is to acknowledge the apparent loss of a building site, and allow the platting of a single <br />6 acre lot from what remains of the 8 acre parcel. The County reached the same conclusions in <br />determining the value of the 2-acre easement acquisition. <br />Although approximately 0.13 acre will be lost to right-of-way in Lot 1, Block 2, the area of Lot 1, <br />Block 2 will remain at 5.07 acres. The wetland delineated by applicant’s consultant is not protected <br />on the City’s inventory, and would therefore be creditable towards dry buildable acreage per City <br />policy. This wetland would, however, be subject to a covenant warning the property owner of the <br />need for permits from other agencies before impacting that wetland. <br />Septic Systems <br />Please review Steve Weckman's comments (Exhibit H). Each proposed lot has primary and alternate <br />drainfield sites available. The existing residence has a nonconforming system which would have <br />to be replaced by the end of 2007 under current code. The alternate sites for the existing residence <br />are slightly limited and would require either a variance or driveway relocation if the house was <br />expanded beyond its current 3-bcdroom status. <br />As noted above, the northwesterly site for Lot 1, Block 3 will be eliminated by road construction. <br />Dry Buildable Acreage for Lot 1, Block 1 <br />The submitted wetland report does not purport to exactly define the boundary of the wetland for <br />proposed Lot 1, Block 1, but is an estimate of the approximate boundary. Staff has calculated the <br />dry buildable area of Lot 1, Block las 4.77 acres based on the submitted survey ^d approximate <br />boundary. The zoning code requires that building lots in the RR-IA zone contain 5 acres of dry <br />buildable land. <br />Applicant’s wetland consultant must confirm the boundary of the wetland and applicant s surveyor <br />must determine whether Lot 1, Block 1 contains the required 5 acres of dry buildable land. If not. <br />Planning Commission should consider whether any of the following options is appropriate: <br />1. Can applicant acquire additional land from a neighboring property? <br />2. Should area within Lot 1, Block 2 be credited toward Lot 1, Block 1 via an outlot <br />with Special Lot Combination across the road? If this results in Lot 1, Block 2,