My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
M20-000009 - mechanical
Orono
>
Property Files
>
Street Address
>
B
>
Bracketts Point Road
>
1400 Bracketts Point Road - 11-117-23-32-0025
>
Permits/Inspections
>
M20-000009 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:30:06 PM
Creation date
6/26/2023 11:11:36 AM
Metadata
Fields
Template:
x Address Old
House Number
1400
Street Name
Bracketts Point
Street Type
Road
Address
1400 Bracketts Point Road
Document Type
Permits/Inspections
Permit Number
M20-000009
PIN
1111723320025
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specification for WSHP SmartSource ALL <br />value for subsequent operation in the field. The brownout trip and recovery levels are a function of the <br />application software and are listed elsewhere in this specification. <br />d. Suction -Line Temp Sensor. Sensing element shall be equivalent to NTC Thermistor —10K ohms @ 25°C, 0.2°C <br />interchangeability. Advanced Thermal Products — Curve Z. NOTE: The Timed (Tenant) Override switch will <br />short out the Room sensor thermistor. Sensing range shall be 0 to 1587 with a resolution of 1°F and an <br />accuracy of +/- 1.57 Maximum Total Error. <br />e. Set point Adjust. The Set point Adjust circuit of a remote room sensor shall consist of a 1.5K -ohm 2 -wire <br />potentiometer. The wiper of the potentiometer will be connected to the analog input. The other lead of the <br />potentiometer is tied to analog common. The 0 —1.5K -ohm range will be interpreted by the base controller <br />as an offset to the current temperature Set point -5 to +5 degrees F or a range of 55 to 95 degrees F (jumper <br />selectable and scaled accordingly in software). <br />f. Fan On/Auto, Heat/Cool/Auto The Room Sensor shall incorporate switches and fixed resistors that present <br />different resistance values to a single analog input which correspond to the fan and operating mode functions <br />detailed below. The room sensor is designed with specific resistance values to coincide with the software in <br />unit control module. <br />g. Temperature Input. Sensing element in the Microtechlll room temperature sensor is equivalent to NTC <br />Thermistor —10K ohms @ 25°C, 0.2°C interchangeability. Advanced Thermal Products — Curve Z. NOTE: The <br />Timed (Tenant) Override switch will short out the Room sensor thermistor. Sensing range shall be 0 to 158°F <br />with a resolution of 1°F and an accuracy of +/- 1.5°F Maximum Total Error. <br />h. Binary Inputs. 18 total (Low Pressure, High Pressure, Emergency Shutdown, 8 -Board level jumpers, 6 <br />thermostat, Occupied/Unoccupied) that employ the Occupied/Unoccupied control. <br />i. The Low Pressure switch shall be sourced with 24VAC or DC, +/-20%. The binary input detection circuit shall <br />be designed such that a minimum of 7mA current flows through the external contacts. <br />J. The High Pressure switch shall be part of an interlock circuit that interrupts power to the on -board <br />compressor relay coil. Since this is a low voltage safety circuit as defined by UL, the designer must apply <br />appropriate spacing as dictated by the relevant UL standards. As part of HP switch state detection, this circuit <br />must sense the current flowing through the on -board compressor relay coil and communicate this <br />information to the HP binary input. The current sensing circuit (Example device: NEC/CEL PS2501-1-A opto- <br />isolator) must be upstream of the High Pressure switch, i.e., between the control output and the HP switch. <br />In the unlikely event that the compressor binary output or HP current sensing circuit fails closed, the HP <br />switch can still perform its intended safety function by opening the compressor relay coil circuit. <br />k. Emergency Shutdown. This binary input will detect the presence of an earth grounded signal, which is <br />supplied by an external, remote set of contacts — such as those provided by a Condenser Loop Water <br />Controller. <br />I. Unoccupied Mode. This binary input will detect the presence of an earth grounded signal, which is supplied <br />by an external, remote set of contacts — such as those provided by a Condenser Loop Water Controller. <br />m. Thermostat inputs G, Y1, Y2, W1, W2, shall detect the presence of 24VAC sourced from the "R" terminal. The <br />binary input conditioning circuitry for these inputs is designed to be compatible with conventional wall <br />thermostats. <br />n. Board Level Jumpers: <br />JP1 Senice.Test Mode <br />JP2 Continuous:'cyding fan <br />JP3 Water:'G1yco1 (Loop tluid) <br />JP4 Freeze fault protection <br />JP5 Room Temperature Set point adjustment range <br />JP6 Local control type (thermostat or room sensor) <br />JP: Primary heating source (compressor or other) <br />]P8 L'4 expansion module (present or not required) <br />3. Binary Outputs: 9 total (Main Fan, Compressor, Reversing Valve, Isolation valve/Pump Request, 3 Board Status <br />LEDs, Room Sensor Status LED, Thermostat "A" output) <br />Job Number: LL2OFE Page Prepared Date: 10/8/2020 <br />Job Name: Brackets Point House 32 of 35 www.DaikinApplied.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.