My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
M20-000009 - mechanical
Orono
>
Property Files
>
Street Address
>
B
>
Bracketts Point Road
>
1400 Bracketts Point Road - 11-117-23-32-0025
>
Permits/Inspections
>
M20-000009 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:30:06 PM
Creation date
6/26/2023 11:11:36 AM
Metadata
Fields
Template:
x Address Old
House Number
1400
Street Name
Bracketts Point
Street Type
Road
Address
1400 Bracketts Point Road
Document Type
Permits/Inspections
Permit Number
M20-000009
PIN
1111723320025
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specification for WSHP SmartSource ALL <br />J. Geothermal (extended range) Operation — Manufacturer shall guarantee "extended range" heat pump units to <br />start and operate continuously in an ambient of 40° F, with entering air and water at 40° F, with both air and water at <br />the flow rates used in the ARI/ISO rating test. A geothermal extended range option shall be made up of a TXV <br />metering device and wrapped condenser coil. Closed cell insulation shall be added to the internal water lines and on <br />suction side refrigerant tubing including refrigerant to water heat exchanger. <br />K. Air Section - The air section of the unit shall be isolated from the compressor and control section with an insulated <br />divider panel to minimize the transmission of compressor noise and to permit operational service testing with the <br />compressor compartment cover removed. <br />L. Filter and Filter Racks — All units shall be provided with a 2" thick, disposable type fiberglass filter installed in a <br />factory mounted four-sided 2" filter frame arranged for side removal. <br />M. Supply and return, condenser water connections — shall be FPT fittings, brazed copper water tubes and securely <br />flush mounted to the cabinet corner post allowing for connection to a flexible hose without the use of a back-up <br />wrench. Condensate drain connection shall not be less than %" FPT fitting securely flush mounted to the corner <br />post. Supply, return, and condensate drain shall be connected to loop and drain piping as detail on mechanical <br />drawings. Piping connections at the unit which require brazing or soldering by the installer (which may damage the <br />unit) shall not be allowed. <br />N. Stainless Steel Drain Pan — Unit shall utilize corrosion resistant closed -cell insulated stainless steel drain pans. A <br />stub out connection shall be provided. The drain pan shall be designed to ensure no pooling of condensate water <br />per ASHRAE 62.2. The unit will be supplied with solid-state electronic condensate overflow protection as standard. <br />Mechanical float switches will not be accepted. <br />0. Sound Package — Available as a factory installed option, units shall utilize sound attenuating compressor blankets <br />with high technology sound attenuating material that is strategically applied within the air handling compartment <br />casings to further reduce sound transmitted by the unit while in operation. <br />P. Coaxial Coil Supply Liquid Auto Flow Regulator - This factory -installed option includes the addition of an automatic <br />flow control valve to set and limit the GPM through the unit. The valve shall have a "replaceable cartridge" <br />capability. The valve shall be rated for 600 psig. (Note: This option will not be available with Internal Water Pump <br />option.). <br />Q. Control System (Microtech III Unit Controller) - <br />1. The unit control board shall be the main component of the system and shall contain the required <br />inputs/outputs to operate a water source heat pump with a single speed fan. <br />2. Unit controller inputs/outputs: The Microtech III controller will be microprocessor -based and have capabilities, <br />performance, and memory sufficient to execute the various functions detailed in this specification. This document <br />will not specify a type, a manufacturer, or a family of microcontrollers to be considered for use. However, at a <br />minimum, the following features are deemed essential: <br />a. Analog Inputs: (Condensate Overflow, Brownout Detection, Suction -Line Temp Sensor, Timed Override <br />Switch, Set point Adjust, Fan Mode — (Heat/Cool/Auto) <br />b. Condensate Overflow. The presence of excessive condensate in the condensate drain pan is detected by a <br />condensate sensor, which consists of a metal terminal ring mounted just below the top of the condensate <br />pan. The analog input dedicated to condensate sensing must be capable of detecting the conductivity of <br />water between the ring terminal and chassis ground. The conductivity trip point is 2.5 micro-ohms. <br />c. Brownout Detection. This analog input will measure the 24VAC input voltage applied to the controller as a <br />means of indirectly monitoring line voltage applied to the unit. The 24VAC input, once rectified, filtered, and <br />fed to an appropriate voltage divider, will be applied to the analog input as a DC voltage level proportional to <br />the input voltage. At a minimum, the measurable range will be between 70 and 120% of the corresponding <br />unit nameplate voltage. Due to the tolerances involved with the various components associated with this <br />approach, calibration will occur during factory test when exactly 100% nameplate voltage is applied to the <br />unit while in cooling mode. The digitized value of the resultant DC voltage applied to the analog input during <br />the calibration period will be saved within the controller (in non-volatile memory) and used as a reference <br />Job Number: LL2OFE Page Prepared Date: 10/8/2020 <br />Job Name: Brackets Point House 31 of 35 www.DaikinApplied.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.