Laserfiche WebLink
1155 SF <br />EXISTING DECK <br />2318 SF <br />EXISTING MAIN LEVEL <br />899 SF <br />NEW GARAGE <br />172 SF <br />FRONT PORCH <br />ADDITION <br />24 SF <br />STAIR ADDITION <br />1060 SF <br />EXISTING UPPER <br />LEVEL <br />2090 SF <br />UPPER LEVEL <br />ADDITION <br />85 SF <br />EXISTING BALCONY <br /> 1/8" = 1'-0" <br />1Main Level <br /> 1/8" = 1'-0" <br />2Upper Level <br />DRAWN BY <br />DESCRIPTION PROJECT # <br />PROJECT ISSUE <br />RE-ISSUE <br />BUILDER a18476 KENRICK AVE. SUITE #202 <br />LAKEVILLE, MN 55044 <br />TEL: 952.428.8200 <br />EM: Dave@DavidCharlezDesigns.com <br />D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S <br />Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of <br />the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, <br />quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction <br />issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or <br />other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer <br />and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size <br />are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be <br />flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific <br />manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with <br />local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult <br />builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design <br />retains rights to all plans and detail shown. <br />2/16/2023 3:38:11 PM 17Square Footage Calculations MISC - Beduhn - CD <br />Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM <br />1340 Vine Place <br />Orono, MN <br />S Q. F T G. C A L C S. <br />Name Sq. Ftg.Level Area Type <br />EXISTING MAIN LEVEL 2318 SF Existing First Floor FINISHED SQ. FTG. <br />STAIR ADDITION 24 SF Existing First Floor FINISHED SQ. FTG. <br />EXISTING UPPER LEVEL 1060 SF Existing Second Floor FINISHED SQ. FTG. <br />UPPER LEVEL ADDITION 2090 SF Existing Second Floor FINISHED SQ. FTG. <br />FINISHED SQ. FTG.5492 SF <br />EXISTING DECK 1155 SF Existing First Floor OUTDOOR SQ. FTG. <br />FRONT PORCH ADDITION 172 SF Existing First Floor OUTDOOR SQ. FTG. <br />EXISTING BALCONY 85 SF Existing Second Floor OUTDOOR SQ. FTG. <br />OUTDOOR SQ. FTG.1411 SF <br />NEW GARAGE 899 SF Existing First Floor UNCONDITIONED <br />SQ. FTG. <br />UNCONDITIONED SQ. FTG.899 SF <br />REVISION SCHEDULE <br />Number Date Issued by <br />CDRev1 1.18.2023 GM <br />CDRev2 1.24.2023 JCB <br />CDRev3 2.2.2023 GM