My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution 7362
Orono
>
Property Files
>
Street Address
>
V
>
Vine Place
>
1340 Vine Place - 07-117-23-42-0031
>
Resolutions
>
Resolution 7362
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:38:31 PM
Creation date
5/25/2023 1:44:51 PM
Metadata
Fields
Template:
x Address Old
House Number
1340
Street Name
Vine
Street Type
Place
Address
1340 Vine Pl
Document Type
Resolutions
Permit Number
LA23-000008
PIN
0711723420031
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS LIST <br />= AIR CONDITIONING <br />= ABOVE FINISHED FLOOR <br />= ALUMINIUM <br />= BOTTOM CHORD BEARING <br />= BOARD <br />= BEDROOM <br />= BUILT IN <br />= BEAM <br />= BOTTOM OF <br />= BEARING <br />= BASEMENT <br />= CABINETS <br />= CANTLIEVER <br />= CEILING <br />= CENTER LINE <br />= CASED OPENING <br />= CONCRETE <br />= CONTINUOUS <br />= CARPET <br />= CERAMIC TILE <br />= CASEMENT <br />= DOUBLE <br />= DEMOLISH OR DEMOLITION <br />= DOUBLE HUNG <br />= DIAMETER <br />= DIMENSION(S) <br />= DOWN <br />= DRYWALL OPENING <br />= DOOR <br />= DISHWASHER <br />= DRAWING <br />= EACH <br />= ENERGY HEEL <br />= ELECTRIC <br />= ELEVATIONS OR ELEVATOR <br />= ENGINEER <br />= ETHYLENE PROPYLENE DIENE M-CLASS <br />= EQUAL <br />= EXTERIOR <br />= EXISTING <br />= FLOOR DRAIN <br />= FINISHED <br />= FLOOR <br />= FOUNDATION <br />= FIREPLACE <br />= FRAMING <br />= FREEZER <br />= FOOTING <br />= FURNITURE <br />= FUTURE <br />= FIXED <br />= GLIDER <br />= GIRDER TRUSS <br />= GYPSUM <br />= GYPSUM BOARD <br />= HEADER <br />= HEIGHT <br />= HEATING VENTILATION AIR CONDITIONING <br />= IN FLOOR HEAT <br />= INSULATION <br />= INTERIOR <br />= LANDING <br />= LINEN <br />= LOCKERS <br />= LOWER LEVEL <br />= LOOKOUT <br />= LUXURY VINYL TILE <br />= LUXURY VINYL PLANK <br />= MAXIMUM <br />= MECHANICAL <br />= MANUFACTURE(R) <br />= MINIMUM <br />= MAIN LEVEL <br />= MASONRY OPENING <br />= NUMBER <br />= NOMINAL <br />= ON CENTER <br />= OFFICE <br />= OPENING <br />= OPTION(AL) <br />= POLISHED CONCRETE <br />= PERIMETER <br />= POCKET <br />= PLUMBING <br />= PLYWOOD <br />= POWDER <br />= POLYVINYL CHLORIDE <br />= REFRIGERATOR <br />= REQUIRED <br />= ROOM <br />= ROD & SHELF <br />= SIMULATED DIVIDED LITE <br />= SMOKE DETECTOR <br />= SMOKE / CARBON MONOXIDE DETECTOR <br />= SINGLE HUNG <br />= SHELVING <br />= SHELVES <br />= SIMILAR OR SIMULATOR <br />= SLIDER <br />= SINK <br />= SPECIFICATION(S) OR SPECIFIED <br />= STEEL <br />= STORAGE <br />= STRUCTURAL <br />= SQUARE FOOTAGE <br />= TO BE DETERMINED <br />= TOP CHORD BEARING <br />= TONGUE AND GROOVE <br />= TOP OF <br />= TREATED <br />= TRANSOM <br />= TYPICAL <br />= UPPER LEVEL <br />= UNFINISHED <br />= VANITY <br />= WOOD <br />= WINDOW <br />= WALK IN CLOSET <br />= WITH <br />= WALKOUT <br />= WASHER <br />A.C. <br />A.F.F. <br />ALUM. <br />B.C.B. <br />BD. <br />BDRM. <br />B.I. <br />B'M <br />B.O. <br />BRG. <br />BSMT. <br />CABS. <br />CANT. <br />CLG. <br />C.L. <br />C.O. <br />CONC. <br />CONT. <br />CPT. <br />C.T. <br />CSMT <br />DBL. <br />DEMO <br />D.H. <br />DIA. <br />DIM(S) <br />DN. <br />D.O. <br />DR. <br />D.W. <br />DWG. <br />EA. <br />E.H. <br />ELEC. <br />ELEV. <br />ENG. <br />EPDM <br />EQ. <br />EXT. <br />EXST. <br />F.D. <br />FIN. <br />FLR. <br />FND. <br />F/P <br />FRMG. <br />FRZ. <br />FTG. <br />FURN. <br />FUT. <br />FX. <br />GLD. <br />G.T. <br />GYP. <br />GYP. BD. <br />HDR. <br />HGT. <br />HVAC <br />I.F.H. <br />INSUL. <br />INT. <br />LDG. <br />LIN. <br />LKRS. <br />L.L. <br />L.O. <br />L.V.T. <br />L.V.P. <br />MAX. <br />MECH. <br />MFG. <br />MIN. <br />M.L. <br />M.O. <br />NO. <br />NOM. <br />O.C. <br />OFF. <br />OP'NG <br />OPT. <br />P. CONC. <br />PERM. <br />PKT. <br />PLMG. <br />PLWD. <br />PWDR <br />PVC <br />REF. <br />REQD <br />RM. <br />R&S <br />S.D.L. <br />SD. <br />SD/CO <br />S.H. <br />SHLVG. <br />SHLVS. <br />SIM. <br />SLD. <br />SNK <br />SPEC. <br />ST'L <br />ST'RG <br />STRUC. <br />SQ. FTG. <br />TBD. <br />T.C.B. <br />T&G <br />T.O. <br />TRD. <br />TRSM. <br />TYP. <br />U.L. <br />UNFIN. <br />VTY. <br />W'D <br />WDW <br />W.I.C. <br />W/ <br />W.O. <br />WSHR. <br />DRAWN BY <br />DESCRIPTION PROJECT # <br />PROJECT ISSUE <br />RE-ISSUE <br />BUILDER a18476 KENRICK AVE. SUITE #202 <br />LAKEVILLE, MN 55044 <br />TEL: 952.428.8200 <br />EM: Dave@DavidCharlezDesigns.com <br />D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S <br />Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of <br />the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, <br />quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction <br />issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or <br />other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer <br />and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size <br />are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be <br />flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific <br />manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with <br />local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult <br />builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design <br />retains rights to all plans and detail shown. <br />2/16/2023 3:38:06 PM 16Schedules & Notes MISC - Beduhn - CD <br />Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM <br />1340 Vine Place <br />Orono, MN <br />GENERAL NOTES <br />1. ALL EXTERIOR WALLS TO BE CONSTRUCTED OF 2x6 STUDS @ 16" O.C. <br />2. ALL INTERIOR WALLS TO BE CONSTRUCTED OF 2x4 STUDS @ 16" O.C. (UNLESS OTHERWISE <br />NOTED) <br />3. WALLS ADJACENT TO GARAGE SPACE SHALL BE 2x6 WITH A 1 HR. FIRE RATING <br />4. STRUCTURAL WALLS TO HAVE A FIRE RATING OF 1 HR. <br />5. ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF STUD <br />6. PROVIDE ROOF VENTILATION 1 SQ.FT. PER 300 SQ.FT. OF ROOF AREA. 50% AT RIDGE AND 50% AT <br />SOFFIT-MIN <br />7.ALL INTERIOR DOOR HEAD HEIGHT TO BE VERIFIED BY BUILDER UNLESS OTHERWISE NOTED. <br />UNDERCUT MIN 1" <br />8. ALL STRUCTURAL MEMBERS TO BE VERIFIED BY MANF. AND A STRUCTURAL ENGINEER. <br />9. ALL WINDOW UNITS ABOVE TUB DECK AND/OR WITHIN 18" OF THE FLOOR AND/OR 24" OF A <br />DOORWAY SHALL BE TEMPERED GLASS <br />10. PROVIDE AN APPROVED ICE AND WATER ROOFING STARTER EDGE PER CODE OR EQUIVALENT <br />11. WRAP ALL CANTILEVERS WITH AN APPROVED POLY AND SPRAY FOAM FLOOR <br />12. SLOPE FINISHED GRADE AWAY FROM THE HOUSE ON ALL SIDES <br />13. 1/2" AIR SPACE ON EACH SIDE OF MICRO-LAM BEAM & MIN 3" BEARING ON CONCRETE <br />14. EXTERIOR RAILING TO BE MIN OF 36" HIGH AND BUILT AS TO NOT ALLOW A 4" SPHERE TO PASS <br />THROUGH <br />15. ALL COMPONENTS TO BE INSTALLED TO MANF. SPEC OR LOCAL CODE <br />16. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY IS TO BE PRESSURE TREATED <br />OR WOOD SPECIES THAT HAS A NATURAL RESISTANCE TO DECAY <br />17. PROVIDE A WATER RESISTIVE GYP BOARD AROUND ALL SHOWERS AND TUBS <br />18. LIGHT OR FAN HOUSING SYSTEM RECESSED THROUGH AN EXTERIOR VAPOR BARRIER SHALL BE <br />OF THE AIR SEALED TYPE OR BE BOXED AND SEALED PER CODE <br />19. PROVIDE DRAFT STOPS PER UBC 708.3 <br />20. FIRE BLOCK ALL CHASES AT EACH FLOOR-CEILING ASSEMBLY OR AT 10' MAX INTERVALS <br />21. ALL SMOKE DETECTORS TO BE HARD WIRED WITH BATTERY BACKUP PER CODE <br />22. MAINTAIN A 6" SEPARATION BETWEEN GRADE AND WOOD <br />23. CAULK AND FLASH AROUND ALL EXTERIOR OPENINGS <br />24. PLUMBING PENETRATIONS IN WALL ASSEMBLY SHALL BE FIRE CAULKED WITH LISTED MATERIALS <br />25. BLOCK PATIO DOORS WITHOUT A DECK <br />26. SMOKE DETECTORS SHALL BE MIN 16" AWAY FROM WALL AND INSTALL TO MANF. SPEC <br />27. NO OPENING IN ROOF WITHIN 5' OF PROPERTY LINES <br />28. 10% OF THE FLOOR AREA IS REQUIRED FOR LIGHT AND VENTILATION IN ALL HABITABLE ROOMS <br />29. ON EXTERIOR, GRIPPABLE HANDRAILS 34" TO 36" IN HEIGHT FROM THE NOSE OF THE STAIRS <br />30. COMBUSTION AIR DUCTS 12" OFF THE FLOOR OR RETURN AIR PLENUM WHEN REQUIRED (IMC703) <br />31. PROVIDE PLUMBING ACCESS AT ALL TUBS EXCEPT WHEN TRAPS & OVERFLOW GLUED <br />32. PROVIDE 50 cfm OR 20 cfm CONTINUOUS VENTILATION OR OPERABLE WINDOW (ASHRAE 62-2001 <br />6.1) <br />33. DRYER VENT TO THE EXTERIOR- INSULATE LAST 3 FEET MIN 36" CLEARANCE TO OTHER <br />OPENINGS: (IMC504.4, 401.52 AND 604.1) <br />34. CERAMIC TILE TO BE APPLIED OVER GREEN BOARD, CEMENT BOARD, WONDER BOARD OR <br />OTHER APPROVED MATERIAL TO A HEIGHT OF 70" ABOVE DRAIN INLET IN SHOWERS. CEMENT BOARD <br />MUST BE USED ON EXTERIOR WALLS UNDERNEATH TILE AND OVER THE VAPOR BARRIER (R307) <br />35. TRUSS PLANS STAMPED AND APPROVED BY MANF. SHALL BE ON THE JOB SITE. ALTERATIONS TO <br />TRUSSES REQUIRE AN ENGINEER'S APPROVAL <br />36. RAFTERS SHALL BE FRAMED TO MIN 1" THICK RIDGE BOARD NOT LESS THAN THE DEPTH OF THE <br />CUT END OF THE RAFTERS OR NAILED TO EACH OTHER WITH A GUSSET PLATE A TIE. THE RIDGE <br />BOARD MUST BE SUPPORTED ON END WALL OR MIN 2x4 COLLAR TIES ARE REQUIRED AT MIN 4" O.C. <br />37. 4-MIL VAPOR BARRIER ON WARM IN WINTER SIDE OF EXTERIOR WALLS AND CEILING. FIRE <br />RETARDANT VAPOR BARRIER MAY BE LEFT UNCOVERED <br />38. WIND-WASH AT AL EAVES, CORNERS, OVERHANGS, AND BY WINDOWS. SHEATHING INSULATION <br />DAM @ CEILING CHANGES <br />39. WEATHER-RESISTIVE BARRIER-i.e. BUILDING WRAP TABLE R703.4 <br />40. HOT WATER PIPING LOCATED OUTSIDE OF CONDITIONED SPACE WILL BE INSULATED TO AT <br />LEAST R-3 <br />41. ATTIC ACCESS DOORS FROM CONDITIONED TO UNCONDITIONED SPACES SHALL BE WEATHERED- <br />STRIPPED AND INSULATED. <br />42. NEW WOOD-BURNING FIREPLACES WILL HAVE TIGHT-FITTING FLUE DAMPERS AND OUTDOOR <br />COMBUSTION AIR. <br />43. FOR WINDOWS WHERE THE LOWEST PART OF THE WINDOW OPENING IS MORE THAN 6' ABOVE <br />THE GROUND, THE LOWEST PART OF OPENING SHALL BE MIN. OF 36" ABOVE THE FINISHED FLOOR. <br />EXCEPTIONS INCLUDE WINDOWS THAT DO NOT OPEN MORE THAN 4", WINDOWS WITH FALL <br />PROTECTION, AND WINDOWS THAT HAVE OPENING CONTROL DEVICES. <br />44. DWELLINGS WITH ATTACHED GARAGES OR FUEL FIRED EQUIPMENT MUST BE EQUIPPED WITH <br />CARBON MONOXIDE ALARMS OUTSIDE OF, BUT NO FURTHER THAN 10' FROM , EACH SLEEPING AREA <br />OR BEDROOM. <br />45. FOOTINGS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 5,000 psi. <br />46. A MIN. 1/2" GYPSUM BOARD MEMBRANE, OR 5/8" WOOD STRUCTURAL PANEL MEMBRANE, SHALL <br />BE PROVIDED ON THE UNDERSIDE OF FLOOR ASSEMBLIES. EXCEPTIONS A.DWELLINGS EQUIPPED <br />WITH SPRINKLER SYSTEM. B.CRAWLSPACES C.PORTIONS OF FLOOR ASSEMBLIES WITH <br />PROPORTIONALLY SMALL AREA. D. FLOOR ASSEMBLIES CONSTRUCTED OF SOLID SAWN LUMBER OR <br />STRUCTURAL COMPOSITE LUMBER WITH MIN. NOMINAL DIMENSIONS OF 2"x10". <br />47. DECKS SUPPORTED BY ATTACHMENT TO AN EXTERIOR WALL SHALL BE POSITIVELY ANCHORED <br />TO THE PRIMARY STRUCTURE AND DESIGNED FOR BOTH VERTICAL AND LATERAL LOADS. <br />48. FLASHING WITH A MIN. 3 1/2" VERTICAL ATTACHMENT FLANGE IS REQUIRED AT THE <br />INTERSECTION OF THE FOUNDATION AND RIM JOIST FRAMING WHEN THE EXTERIOR WALL <br />COVERING DOES NOT LAP THE FOUNDATION INSULATION. THE FLASHING MUST EXTEND A MIN. OF 1" <br />BELOW THE FOUNDATION PLATE LINE, AND THE REQUIRED WATER-RESISTIVE BARRIER MUST LAP <br />OVER THE ATTACHMENT FLANGE. <br />49. BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS <br />D O O R S C H E D U L E <br />Tag Door Size Door Type Quantity Head Height Level <br />101 ELSFD12070 Marvin Elevate Sliding French 4-Panel 1 7' - 2"Exst. Raised First Floor <br />102 UBFLD9080-3P Marvin Ultimate Bi-Fold 1 7' - 11 1/2"Existing First Floor <br />103 ELIFD3080 Marvin Elevate Inswing French 1-Panel 1 7' - 11 1/2"Lowered First Floor <br />104 ELIFD3080 Marvin Elevate Inswing French 1-Panel 1 7' - 11 1/2"Lowered First Floor <br />105 9'-0" x 8'-0"Single Overhead Garage Door 1 8' - 0"Grade <br />106 18'-0" x 8'-0"Double Overhead Garage Door 1 8' - 0"Grade <br />107 9'-0" x 8'-0"Single Overhead Garage Door 1 8' - 0"Grade <br />108 ELIFD3080 Marvin Elevate Inswing French 1-Panel 1 7' - 11 1/2"Existing First Floor <br />109 32" x 80"Single Swing (Interior)1 6' - 8"Exst. Raised First Floor <br />110 32" x 80"Single Swing (Interior)1 6' - 8"Exst. Raised First Floor <br />111 60" x 80"Double Swing (Interior)1 6' - 8"Lowered First Floor <br />112 36" x 80"Single Swing (Interior)1 6' - 8"Lowered First Floor <br />113 36" x 80"Single Pocket (Interior)1 6' - 8"Lowered First Floor <br />114 36" x 80"Single Swing (Interior)1 6' - 8"Lowered First Floor <br />115 36" x 80"Single Swing (Interior)1 6' - 8"Existing First Floor <br />116 36" x 80"Single Pocket (Interior)1 6' - 8"Lowered First Floor <br />117 36" x 80"Fire Door - 20min. Rated 1 6' - 8"Lowered First Floor <br />118 36" x 80"Single Pocket (Interior)1 6' - 8"Lowered First Floor <br />201 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />202 36" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />203 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />204 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />205 60" x 80"Double Swing (Interior)1 6' - 8"Existing Second Floor <br />206 30" x 80"Single Pocket (Interior)1 6' - 8"Existing Second Floor <br />207 48" x 80"Double Swing (Interior)1 6' - 8"Existing Second Floor <br />208 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />209 72" x 80"Double Bi-Pass Door (Interior)1 6' - 8"Existing Second Floor <br />210 72" x 80"Double Bi-Pass Door (Interior)1 6' - 8"Existing Second Floor <br />211 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />212 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />213 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />214 36" x 80"Single Pocket (Interior)1 6' - 8"Existing Second Floor <br />215 36" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />216 36" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />217 36" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor <br />218 USPD12070 Marvin Ultimate Sliding Patio 3-Panel 1 7' - 2"Existing Second Floor <br />Grand total: 36 <br />M A R V I N W I N D O W S C H E D U L E <br />TagWindow CodeWindow TypeQuantity Head Height Level Room Location <br />01ELCAP5763Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor <br />02ELAWN5763Marvin Elevate Awning 1 1' - 8 7/8"Exst. Raised First Floor <br />03ELCAP7363Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor <br />04ELCAP7319Marvin Elevate Casement Picture 1 1' - 8 7/8"Exst. Raised First Floor <br />05ELCAP4963Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor <br />06ELCAP4963Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor <br />07ELCAP4963Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor <br />08ELAWN4919Marvin Elevate Awning 1 1' - 8 7/8"Exst. Raised First Floor <br />09ELAWN4919Marvin Elevate Awning 1 1' - 8 7/8"Exst. Raised First Floor <br />10ELAWN4919Marvin Elevate Awning 1 1' - 8 7/8"Exst. Raised First Floor <br />11ELCA3771Marvin Elevate Casement 1 8' - 0"Existing First Floor <br />12ELAWN3719Marvin Elevate Awning 1 2' - 0 7/8"Existing First Floor <br />13ELCA3771Marvin Elevate Casement 1 8' - 0"Existing First Floor <br />14ELAWN3719Marvin Elevate Awning 1 2' - 0 7/8"Existing First Floor <br />15ELCA3355Marvin Elevate Casement 1 8' - 0"Lowered First Floor <br />16ELCA3355Marvin Elevate Casement 1 8' - 0"Lowered First Floor <br />17ELCAP3371Marvin Elevate Casement Picture 1 8' - 0"Grade <br />18ELCAP3371Marvin Elevate Casement Picture 1 8' - 0"Grade <br />19ELCAP3371Marvin Elevate Casement Picture 1 8' - 0"Grade <br />20ELAWN3323Marvin Elevate Awning 1 8' - 0"Lowered First Floor <br />21ELAWN3323Marvin Elevate Awning 1 8' - 0"Lowered First Floor <br />22ELCA3371Marvin Elevate Casement 1 8' - 0"Lowered First Floor <br />23ELCAP4971Marvin Elevate Casement Picture 1 8' - 0"Lowered First Floor <br />24ELCA3371Marvin Elevate Casement 1 8' - 0"Lowered First Floor <br />25ELCAP5771Marvin Elevate Casement Picture 1 8' - 0"Existing First Floor <br />26ELCA3343Marvin Elevate Casement 1 7' - 0"Exst. Raised First Floor <br />27ELCAP5747Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor <br />28ELCAP5763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />29ELCAP7363Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />30ELCAP3763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />31ELCAP3763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />32ELCAP3763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />33ELCAP3763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />34ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />35ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />36ELAWN3719Marvin Elevate Awning 2 7' - 0"Existing Second Floor <br />37ELAWN3719Marvin Elevate Awning 1 7' - 0"Existing Second Floor <br />38ELCA3763Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />39ELCA3763Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />40ELCA3763Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />41ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />42ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />43ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />44ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />45ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />46ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />47ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />48ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />49ELAWN3719Marvin Elevate Awning 1 7' - 0"Existing Second Floor <br />50ELAWN3719Marvin Elevate Awning 1 7' - 0"Existing Second Floor <br />51ELAWN3719Marvin Elevate Awning 1 7' - 0"Existing Second Floor <br />52ELAWN3323Marvin Elevate Awning 1 7' - 0"Existing Second Floor <br />53ELAWN3323Marvin Elevate Awning 1 7' - 0"Existing Second Floor <br />54ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />55ELCAP4963Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />56ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />57ELCAP5771Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />58ELCA3763Marvin Elevate Casement 1 7' - 0"Existing Second Floor <br />59ELCAP3771Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />60ELCAP4971Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />61ELCAP7371Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />62ELCAP4971Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />63ELCAP5763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor <br />Total Windows: 64 <br />REVISION SCHEDULE <br />Number Date Issued by <br />CDRev1 1.18.2023 GM <br />CDRev2 1.24.2023 JCB <br />CDRev3 2.2.2023 GM
The URL can be used to link to this page
Your browser does not support the video tag.