Laserfiche WebLink
SEPTIC SYSTEM INVENTOR Y <br />Address: 925 Brown Rd. N. PID: 27-118-23 34 0001 <br />Building Type residence #BRs/GPD: 3 #Systems 1 Units Billed 1 <br />Permit#: none Date of Permit: Installer: unknown <br />System Type standard trench Experimental: no Appliances Indry <br />SYSTEM CONDITION <br />Conformity: 3 Tank Condition: 9 DF condition: 11 Failure Pot: medium <br />SEPTIC TANKS <br />Material: precast concrete <br />Setback to Bldg: 15 <br />Capacity: 1000,600 <br />Cesspool: no <br />DRAINFIELD <br />Length of Lines 240 # Lines: 3 Trench Width: 2.5 <br />Treatment Area: 600 Type of Filter rock Soil Boring: yes <br />Tile Size: 4 Under Tile PercRate: 40 <br />Setback DF-Bldg: 40 DFHt above Wt: 0 <br />Soil Type: clay, sandy clay Limitations: water table <br />WELL DATA <br />Setbacks - Well-Tanks: 50 <br />Pump Type: subm. <br />INSPECTION RECORD <br />Well-DF: 75 Report in File <br />Depth: 152 Diameter: 4 Method: drilled <br />PUMPOUT RECORD <br />DATE <br />imi%\ <br />8/5/86 <br />6/28/88 <br />10/5/90 <br />5/27/92 <br />9/3/95 <br />7/10/96 <br />8/26/98 <br />DESCRIPTION <br />no surfacing <br />no surfacing <br />no surfacing <br />no surfacing <br />no surfacing <br />non-conforming-slight surfacing,repair by <br />non-conforming-slight surfacing,repair b <br />non-compliant-repair by 12/31/2002 <br />COMPLIANCE DATE <br />2 <br />2 <br />2 <br />2 <br />2 <br />3 <br />• <br />3 <br />3 <br />1/1/80 <br />11/1/85 <br />9/1/88 <br />10/19/91 <br />GALLONS <br />1650 <br />1500 <br />1750 <br />1500