M19-000050 - HVAC
Orono
>
Property Files
>
Street Address
>
S
>
Saint Andrews Street
>
4665 St. Andrews Street - 06-117-23-31-0012
>
Permits/Inspections
>
M19-000050 - HVAC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:15:17 PM
Creation date
4/3/2023 10:59:21 AM
Metadata
Fields
Template:
x Address Old
Address
4665 St. Andrews St
Document Type
Permits/Inspections
PIN
0611723310012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Directions -In order to determine the makeup air, Table 501.4.1 must be filled out (see below(. Form ost new installations, column Awl II be appropriate, however, if <br />atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is negative, no additional makeup air <br />will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to <br />the last line of section D. <br />Table 501.4.1 <br />PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS <br />Additional combustion air will be required for combustion appliances, see KAIR method for calculations <br />One or multiple power <br />One or multiple fan- <br />One atmospherically vent <br />Multiple atmospherical - <br />vent or direct vent ap- pliances <br />assisted appliances and power <br />gas or oil appliance or one solid <br />ly vented gas or oil appliances <br />or no combus- tion appliances <br />vent or direct vent appliances <br />fuel appliance <br />or solid fuel appliances <br />Column D <br />Column A <br />Column B <br />Column C <br />1. <br />0.15 <br />0.09 <br />0.06 <br />0.03 <br />a) pressure factor <br />(cfm/sf} <br />b) conditioned floor area (sf) (including <br />4636 <br />unfinished basements) <br />Estimated Nouse Infiltration (cfm): (1a <br />69� <br />x 1b] <br />Z. Exhaust Capacity <br />a) continuous exhaust -only ventilation system <br />ERV=O <br />(cfm); (not applicable to ba- lanced ventilation <br />systems such as HRV) <br />b) clothes dryer {cfm) <br />135 <br />135 <br />135 <br />135 <br />c) 80% of largest exhaust rating (cfm); <br />720 <br />Kitchen hood typically <br />(not applicable if recirculating system or if <br />powered makeup air is electrically interlocked <br />d) 80% of next largest exhaust rating <br />Not <br />(cfm); bath fan typically <br />Applicable <br />(not applicable if recirculating system or if <br />powered makeup air is electrically interlocked <br />Total Exhaust Capacity (cfm); <br />o �� <br />[2a+2b +2c+2d] <br />V <br />3. Makeup Air Quantity (cfm) <br />855 <br />a) total exhaust capacity (from above) <br />b) estimated house infiltration (from <br />695 <br />above) <br />Makeup Air Quantity (cfm); <br />[3a —36] <br />(if value is negative, no makeup air is needed) <br />6 O <br />160 I <br />4. For makeup Air Opening Sizing, refer <br />6"Passive <br />to Table 501.4.2 <br />A. Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent <br />appliances may be used.) <br />B. Use this column if there is one fan -assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be included.) <br />C. Use this column if there is one atmospherically vented (other than fan -assisted) gas or all appliance per venting system or one solid fuel appliance. <br />D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid <br />fule appliances. <br />