Laserfiche WebLink
on a urooertv using an ISTS. A building permit will not be issued when the proposed work would <br />preclude the use of the only future drainfield site approved bv the City. <br />G. Conditional Use Permit and Zoning Variance Applications. No conditional <br />use permit or zoning variance application shall be approve*? for a property until the existing on«sitc <br />sewage treatment system ISTS has been confirmed as being of adequate capacity for the anticipated <br />use, If expansion or replacement of the o n»sit e system ISTS is required, an-on -site- system a site <br />evaluation and design must be approved by the City prior to the approval of a conditional use permit <br />or zoning variance. If the change in use intensifies the strength or quantity of flow for the on-site <br />system ISTS. an alternate site o r-fliture expansio n area (if available) must be designated and <br />protected. <br />H. Subdivision Applications. No subdivision, lot division or replatting for the <br />purpose of creating a new building site, which property includes the use of on-s ite systems ISTS. <br />shall be approved by the City until a site evaluation report and system design when required has been <br />reviewed and approved, and all existing systems have been inspected and certified by the City as <br />being in compliance with this Section. <br />1. Each new lot which is not farther subdhridable under the lot area standards <br />o f the zo ning code .-shall have tested and approved primary and alternate drainfield sites. Each newly <br />created lot regardless of acreage and which is intended for the development of a residence shall have <br />approved primary and alternate drainfield sites. <br />2. Each new lot co ntaining less than 5 acres in dry buildable area shall have <br />tested and appro ved primary and alternative drainfield sites; Each new lot with an existing residence <br />connected to an ISTS must have either two future drainfield sites or one future site and a “compliant ” <br />existing ISTS which is expandable to suit a minimum five bedroom residence (750 GPDV <br />3. For all lot s co ntaining less than 5 acres o f diy buildable area, the site <br />evaluatio n report shall also include detailed system design specificatio ns as nor mally required for <br />building permit applicatio ns. Each proposed lot shall be capable of sustaining a five bedroom <br />residence and two drainfield sites to serve the dwelling including those lots with existing residences. <br />4. Fo r each propo sed lot , drainfield sites and system designs shall be capable <br />o f serving a 5 bedroo m ho me (75 0 GPD Design Flo w Rate): <br />5. 4 As part of any subdivision, the owner shall grant to the City in a form <br />approved by the City a perpetual right of entry to allow for the future inspection of all systems, which <br />right of entry may be filed in the chain of title for the property. <br />Subd. 5. System More Restrictive Design and Construction Standards. All <br />system ISTS permit applications, site loc atio ns evaluations, design specifications, construction <br />Page 10 of 22