My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1990-05-25 Septic System Engineering Report
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road
>
4360 Bayside Road - 06-117-23-12-0001
>
Septic
>
1990-05-25 Septic System Engineering Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:23:08 PM
Creation date
3/3/2023 11:23:48 AM
Metadata
Fields
Template:
x Address Old
House Number
4360
Street Name
Bayside
Street Type
Road
Address
4360 Bayside Rd
Document Type
Septic
PIN
0611723120001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S -P TESTING, INC. <br />951 KATYDID LANE <br />ST. MICHAEL, MN 65379 <br />4073696 <br />Steven B. Schirsere <br />May 25, 1990 <br />Jim Olson <br />4360 Bayside Rd. <br />Orono, Henn. Co., MN <br />This system is Designed for a Type 1, three bedroom home and in accordance <br />with the Minnesota Pollution Control Agency Chapter 7080 and local <br />ordinances. <br />This site has an existing system with a surface outlet which is not a <br />legal system and is considerd a failing system. The Olsons bought <br />the home In the fall of 85'. This system would have been illegal at <br />that time also. The soil condidtions would be the same today as <br />in 1985. <br />The soils on this site are typical of SCS soils mapped - KkB - Kilkenny <br />loam. A seasonally high water table was located at 18", 28" t 300, <br />(mottled soil). Due to the seasonally high water table, a Pressurized <br />Mound System will need to be installed. The bottom of the rock bed <br />must be located at least 3' above the seasonally high water table. <br />The soils at a depth of 12" have a percolation rate averaging 5.4 <br />min/inch and are adequate for treating septic effluent. <br />A pumping chamber will need to be installed to lift the effluent to the <br />treatment area. <br />The existing tanks are a block type s will need to be replaced. Pump <br />1� fill with soil. <br />The manifold and supply line pipe must have back drainage to the pumping <br />chamber. The distribution pipes shall have their ends capped. Be sure <br />the rock and sand fill material are clean. The sod layer below the <br />entire mounded area must be turned over, just b►eak up the sod, be sure <br />not to over work. <br />The power supply and switches must be located outside the manhole and <br />pumping chamber in a weather proof enclosure. A warning device must be <br />installed with a light and sound device, this is in case of a pump failure. <br />(Mercury floats are a good method). <br />CONT'D <br />Self and Percolation Toole <br />Sepik System Design <br />
The URL can be used to link to this page
Your browser does not support the video tag.