My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
M18-000003 - mechanical
Orono
>
Property Files
>
Street Address
>
W
>
Wood Duck Trail
>
2868 Wood Duck Trail - 33-118-23-24-0011
>
Permits/Inspections
>
M18-000003 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:24 PM
Creation date
2/22/2023 2:44:02 PM
Metadata
Fields
Template:
x Address Old
House Number
2868
Street Name
Wood Duck
Street Type
Trail
Address
2868 Wood Duck Trail
Document Type
Permits/Inspections
PIN
3311823240011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section B <br />Ventilation Method <br />(Choose either balanced or exhaust only) <br />Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recovery❑ <br />Exhaust only <br />Ventilator) —cfm of unit in low must not exceed continuous <br />Continuous fan rating in cfm <br />ventilation ratingby more than 100%. <br />Low cfm:�� <br />High cfm: <br />QG <br />v V <br />Continuous fan rating in cfm (capacity must not exceed <br />continuous ventilation rating by more than 100%) <br />Directions - Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or ERV's. <br />Enter the low and high cfm amounts. Low cfm airflow must be equal to or greater than the required continuous ventilation rate and <br />less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the ventilation fan must not exceed 80 cfm.) <br />Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. <br />Section C <br />Ventilation Fan Schedule <br />Description Location Continuous Intermittent <br />Directions - The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for continuous <br />or intermittent ventilation. The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating <br />and less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the continuous ventilation fan must not <br />exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. <br />Section D <br />Ventilation Controls <br />(Describe operation and control of the continuous and intermittent ventilation) <br />ERV has wall control set to 30%=93 CFM <br />ERV has wall control set to 60%=186 CFM <br />Directions - Describe the operation of the ventilation system. There should be adequate detail for plan reviewers and inspectors to verify design and <br />installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. If exhaust fans <br />are used for building ventilation, describe the operation and location of any controls, indicators and legends. If an ERV or HRV is to be installed, describe how <br />it will be installed. If it will be connected and interfaced with the air handling equipment please describe such connections as detailed in the manufactures' <br />installation instructions. If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper <br />operation, such interconnection shall be made and described. <br />
The URL can be used to link to this page
Your browser does not support the video tag.