Laserfiche WebLink
OCT-31-Ol UED 12:12 W DEEPHAVEN CITY HALL FAX MX 16124741274 P. 12 <br />Section 330:00 <br />a uurge or balancing lank, ihc point of discharge shall be at least six (6) inches <br />above tlie rim of tlie tank. Ifa hose connection from a sill cock or other plumbing <br />fixture is to be used for supplying make-up water, then an approved vacuum <br />breaker shall be insialletl between the sill cock or control valve at the fixture and <br />the hose comiection. Any sill cock used for this seivicc shall be located above <br />ground level. No over-the-rira fill spout will be accepted unless located under a <br />diving board or installed in a manner approved by the Health Officer so as to <br />remove any Irazard. <br />The systems supplying recirculated water and make-up water to the pool shall be <br />constructed in conformance with die City Plumbing Code. <br />Section 330:22. Main Qulleis. <br />The main outlets, for purposes of recirculation and emptying the pool, shall be so <br />located as to provide at least one outlet at the deepest point in the pool if the pool <br />width docs not exceed twenty (20) feet. If the pool width is more than twenty <br />(20) feet, multiple outlets shall be provided and spaced not more than twenty (20) <br />feet apart, nor more than ten (10) feet from walls. All main outlets shall be <br />equipped with gratings having an area of openings not les.s than four times the <br />cross-sectional area of tlie outlet pipe. The gratings shall be of such design so that <br />they cannot be readily removable by bathers and will not injure ba:hers' fingen. <br />Pools shall be equipped with facilities for completely emptying the pool and other <br />drainage by gravity if elevations permit, and tlie discharge of the pool water to the <br />sanitary sewer, or other suitable disposal unit acceptable to the Community Health <br />Board, shall be at the rate not exceeding 250 gallons per minute. No direct <br />connection shall be made to the sewer. The outlet from the pool recirculation <br />systems shall terminate at least six (6) inches above the receptacle connected to the <br />sewer. The drainage system shai: be constructed in conformance with the <br />provisions of the City Plumbing Code and under the supervision of a licensed <br />plumber. Water drained from U. pool shall not be discharged to the sanitary <br />sewer system during periods of rain or storms. <br />Section 330:24. Heaters. Gas-fircd swimming pool heaters and swimming pool boilers shall bear <br />the American Gas Association seal of approval. Oil burning equipmer* * all bear the <br />Underwriters Laboratory seal of approval. <br />Section 330:26. Water Sunniv. Water supplies se'.'ingall swimming pools shall be of a safe <br />sanitary quality or otherwise acceptable to the Community Health Board. The installation of the <br />pool water supply piping and connection to the source of supply shall be under the supervision of <br />Q licensed plumber.1