My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-09-2003 Council Packet
Orono
>
City Council
>
2003
>
06-09-2003 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2023 4:13:58 PM
Creation date
2/8/2023 1:26:59 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
451
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1 . Ftopehies with major topographic changes, prohibiting a property owner to access the <br />lake, are permitted to have one set of 4’ wide stairs with 32 s.f. landings to access the lake <br />shore; <br />2. The proposal reduces hardcover within the 0-75 ’ setback zone; <br />3. Removd of the existing stairs and retaining wails requiring filling in the bluff impact <br />zone where filling is not permitted. Stairs and landings are permitted within the bluff <br />impact zone; <br />4. The proposal does not address how the hardcover is screened from views on the lake or <br />how the lake will be protected (erosion control plan) during construction; <br />5. No more than SO cubic yards of fill should be necessary to complete the proposed project; <br />6. There is an existing deck within the 0-75 ’ setback zone which is nonconforming and in <br />need of structural repairs. The property owners were notified in a previous resolution that <br />structural repairs to the deck would require City approval; and <br />7. Other issues raised by the Planning Commission. <br />Staff Rcconimcndatioiis: <br />Staff recommends approval of variances to replace existing retaining walls and steps within 75 ’ <br />of the OHWL of Lake Mirmetonka as propos^ with the following conditions: <br />1 . The existing deck within the 0-75 ’ setback zone requires structural repairs and will <br />not be permitted to be replaced once it has been removed; and <br />2. Prior to issuance of the necessary City permits, the following must be submitted and <br />approved by the City Engineer: <br />a. A detailed plan and profile design, including sections on either side of the <br />stairway and profile showing how plantings will screen the hardcover from the <br />lakeside. Plans should include existing structures, lot lines, proposed and <br />existing contours, etc.; <br />b. Calculations of the necessary amount of excavation and fill for the project; <br />and <br />c. A detailed erosion and sediment control plan. <br />it03~2894 Douglas and Roban Smith <br />5/14/2003 <br />Page 4 of 4 <br />A
The URL can be used to link to this page
Your browser does not support the video tag.