My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
04-19-2004 Planning Packet
Orono
>
Agendas, Minutes & Packets
>
Planning Commission
>
Packets
>
2000-2009
>
2004
>
04-19-2004 Planning Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2023 11:42:11 AM
Creation date
1/26/2023 11:34:17 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
381
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
We plan to modify the existing roof layout and construction. This vwukJ allow for <br />elimination of the current 'bathtub' flat area that exists and provide a potential <br />mechanical attic area. The attic mechanical area would provide an area for equipment <br />that is sheiiered. easily maintained and accessible. <br />Mechanical Systems <br />Several modifications to the mechanical systems are planned to serve the existing <br />facility and to acconnmodate the proposed alterations and addi'Jons. These include <br />replacing several air handiirtg systems, such as; the kitchen makeup unit, the units <br />serving the locker rooms, replaong the kitchen exhaust system, and extending the Are <br />protection system, replacing the larger chiller and chilled water pumping/piping system, <br />removing the fan coil units and piping system, and providing a new energy efTident direct <br />digital control (DOC) temperature control system. <br />Electrical Systems <br />Power distribution will need to be modified and extended in remodeled areas and <br />building additions. New receptacles, equipment services and motor power di-Ku-buton <br />will be added to accommodate remodeled areas and building additions. <br />The existing telephone, sound, and fire alarm systems will be mod fled and extended to <br />eooonvnodate remodeled areas and building additions. <br />The electrical utility pad-mounted transformer and pad-mounted generator will be moved <br />to aocomrrxxlate the Casual Dining addition. A relocated electrical utility transformer will <br />be located on the site to re-feed the electrical building service. A new natural gas <br />generator will be located on site to serve the emergency electrical power distribution. <br />Site Work <br />The existing parking area accommodates approximately 270 parking spaces. The <br />estimated future need b 234 spaces. The proposed remodeling and addition will not <br />have a need for increased parlcing. The Cocntiy Qub is a member based use. not an <br />open commercial use. The project does not project an increase in membership. <br />The new service/delivery area will eliminate a substantial amount of paved roadway, <br />which will be converted to green space and plantings.
The URL can be used to link to this page
Your browser does not support the video tag.