Laserfiche WebLink
«ds>3is2 <br />October 13,200S <br />Pegel <br />. ^ <br />Revised Plan Requires Planned Residential Development (PRD) Approval <br />Per the discussions at the September Planning Commission meeting, the applicant is proposing a <br />revis ed plat that places all six proposed residences in the northwesterly quadrant of tlie site. This <br />plan preserves additional areas of existing woodland as compared to the original plan, and <br />preserves the open space character at the southeast corner of the property by eliminating the <br />proposed residence at that site. All six lots will be served by tlie private road, with no separate <br />driveway accesses to Watertown Road. <br />In order to accommodate this layout, individual lot areas and widths have been reduced below <br />the 2.0 acre area / 200 ’ width standards of the RR-IB District. However, the overall dry <br />buildable area of 14.3 acres would calculate to a proposed density of 2.38 acres per unit. <br />This proposal must 'je reviewed as a Planned Residential Development (PRD) per Zoning Code <br />Sections 78-601 thru 78-609. <br />Revised Lot Layout and Lot Standards <br />Note the' the intent of staff and the applicant was to retain the 50’ front/rear, 30’ side setbacks of <br />the RR-IB zone, while making the lots more compact in area and width to allow for preservation <br />of the long views from Watertown Road. <br />Lot 1. Block 1 is at the NW comer of the property, set up for an east-facing walkout with septic <br />sites at the rear comer of the site. This area of the property is an open field with long views to <br />the east t ad southeast. The lot abuts the proposed cul-de-sac as well as the extension of the road <br />corridor to the north boundary, and the house will overlook the cul-de-sac. The east half of tlie <br />lot will be regraded in order to accommodate the front walkout. Setbacks as depicted are <br />appropriate and correct, except that the 50’ front setback should be carried around the ‘temporary <br />cul-de-sac ’ as if it vwre permanent, rather than being measured from the straight section of road <br />corridor. Lot width is defined at 181’ - lot area is 1.47 acres. <br />I.ot 2. Block 1 is directly south of Lot 1. This lot is all open field. Proposed septic sites are in the <br />west half of the lot. Fill and grading is proposed to allow for a driveway access at tlie north end <br />of the lot, as the frontage along the private road gets much sleeper heading south. Setbacks as <br />depicted are appropriate and correct. The defined lot width is 180’ - lot area is 1.35 acres. <br />I .m3. Block 1 is south of Lot 2, Block 1, in a wooded area. Proposed septic sites are in the <br />northwest comer of the property. Grading is proposed at the east and northeast portions of the <br />lot to accommodate a driveway on steep slopes. A portion of the wooded area will be removed <br />to accommodate the house, but still leave a substantial amount of woods along the soutli and <br />southwest sides of the site. Lot width is 188’ - lot area is 1.41 acres. <br />In general, the three lots in Block 1 will liave limited area for amenities such as pools, tennis or <br />sport courts, outbuildings, etc. due to the smaller lot areas wliile still accommodating septic sites <br />and the standard 2-acre zone principal structure setbacks. Special covenants may be needed on <br />these three lots to document the individual site limitations.