Laserfiche WebLink
#05-3080 <br />January 18,2005 <br />Page 5 of 10 <br />Building Height <br />Building height is regulated similar to other zoning districts throughout the City. A <br />maximum height of 30’, measured from the highest point of the existing grade, and a 2 'A <br />story maximum is required. The applicants liave proposed 1 'A story walkouts with <br />unconventional roof lines. <br />High Side Measurement <br />The highest point of the existing grade at the proposed building sites for the west and <br />northeast cluster is approximately 1024 and at the southeast cluster approximately 1020. <br />The applicants have proposed first floor elevations (FFE) of 1020, 1019, and 1014.5 for <br />the west, northeast and southeast cluster respectively. At the high side to the peak the <br />buildings measure approximately 31 feet. Because the applicants have proposed to lower <br />the sites at the high side of the buildings approximately 4 feet at the western cluster, 4.5 <br />feet at the northeastern cluster, and 5.5 feet at the southeastern cluster, the actual defined <br />heights (again on the high side) are only 27 feet, 26.5 feet and 25.5 feet. This meets <br />Zoning Ordinance requirements for building height. <br />Walk-Out or Low Side Measurement <br />Although the high side measurement dctcmiincs the defined building height, staff thought <br />it would be appropriate to discuss the walk-out or low side height measurement as the <br />buildings appear much taller due to the sloped roof lines. <br />The proposed basement elevations are 1009.4, 1008.8, and 1003.9 for the west, northeast <br />and southeast clusters respectively. From the basement elevation to the peak the <br />buildings measure approximately 41 feet. However, staff finds that the walk-out facade <br />of the building will appear somewhat shorter as berming and retaining is proposed to the <br />edge of the property boundaries to lessen the impacts of adjoining neighbors. For <br />example, the proposed grade at the northern property boundary (adjoining Sugarwoods) <br />is 1024 which would have the visual appearance that approximately 15 feet of the facade <br />is hidden. At the northeast comer of the site, bemiing will go to 1018 visually hiding <br />approximately 9 feet of the facade. The southeastern walk-out facades will be the most <br />visible with respect to total fii9ade exposure. <br />Parking Requirements <br />Location <br />As noted above the property nearly meets all required setbacks. All stalls will be located <br />on the west side of the building, 5 feet from the lot line adjacent to the business zoned <br />properties to the west. The applicants have shown a turn-around at the end of the most <br />northwesterly parking area. This tum-around docs not meet the required 10 ’ setback, but <br />provides a necessary function for tnis dead-end lot, and is located so as to be usable for a <br />future service road comicction to the west. <br />Number of Stalls <br />The Zoning Ordinance requires i stall for ever 200 s.f. of floor area for all professional <br />of fice uses. Under this calculation Uic City would require 171 stalls to be constructed for