My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
09-26-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
H
>
Homestead Trail
>
1175 Homestead Trail - 28-118-23-32-0017
>
Septic
>
09-26-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:04 PM
Creation date
8/16/2022 2:18:04 PM
Metadata
Fields
Template:
x Address Old
House Number
1175
Street Name
Homestead
Street Type
Trail
Address
1175 Homestead Trail
Document Type
Septic
PIN
2811823320017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br />www.SepticResource,com (vers 15.2) <br />Property Owner: <br />Site Address: <br />Dave Mariani <br />1180 Homestead Trait <br />Date: 5/15/2018 <br />PID: 2811823320017 <br />Comments: Duel rock bed using un level distribution (Primary site) upper rock bed <br />instructions: = = enter data = adjust if desired = = computer calculated - DO NOT CHANGE! <br />i =bedroom Type �l Residential System <br />300 GPD design flow <br />=Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />a 1500 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 25 ft. long rockbed <br />a, 10.0 ft rockbed width 25.0 ft rockbed length <br />7, 3.0 ft tateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />s, laterals 23.0 feet long 8.0 perfs / lateral 24 1perfs total <br />(1 /2 a perf means the first perf starts at the middle feed manifold) <br />9) 7/32 inch perfs at =feet residual head gives 0 56 gpm flow rate per perforation <br />for this perf size Et spacing, Ft pipe size on line 12, max perfs/lateral = 30 tine #8 must be less > OK <br />lot F 4.0 doses per day ( 4 minimum) <br />11 ) 75 gallons per dose (treatment volume) <br />2.00 5x <br />12 2.00 inch diameter laterals must be used to meet 'Ax pipe volume" requirement <br />2.00 3x <br />13) feet of 2.0 inch supply line leads to ##### gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />too ###### gallons TOTAL pump out volume (treatment + drainback) <br />,a feet vertical lift from pump to mound laterals, leads to a: <br />u,r 14 GPM @ ##### feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 500 I gal Dose tank (code minimum) 500 gal Dose tank (design size / LUG req'd) at gpi <br />leads to a <br />18) ###### inch swing on Demand float, or timed dosing of ##### min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow) ##### hrs OFF test and adjust as necessary) <br />19) Winches <br />inches from bottom of tank to "Pump OFF" float <br />,0) inches from bottom of tank to "Pump ON" float, or 12 inches to "Timer ON" float if time dosed <br />21) from bottom of tank to "Hi Level" float, or ##### inches to "Hi Level" float if time dosed <br />22) ###### gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.