My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
09-26-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
H
>
Homestead Trail
>
1175 Homestead Trail - 28-118-23-32-0017
>
Septic
>
09-26-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:04 PM
Creation date
8/16/2022 2:18:04 PM
Metadata
Fields
Template:
x Address Old
House Number
1175
Street Name
Homestead
Street Type
Trail
Address
1175 Homestead Trail
Document Type
Septic
PIN
2811823320017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code ,Mound Design <br />www.SepticResaurce.com (vers 15.2) <br />Property Owner: Date: <br />Site Address: 1180 Homestead Trail PID: <br />Comments: Pressure dis. <br />instructions: = enter data 0 = adjust if desired = computer calculated - DO NOT CHANGE! <br />I)F 47 bedroom Type Residential System <br />,) 600 GPD design flow <br />31 Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />di 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />1.2 GPD/ft2 mound sand loading rate contour loading rate of F 127 req's a min =ft. long rockbed <br />r 107 ft rockbed width 50.0 ft rockbed length <br />71 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />Lend feed manifold connection <br />Laterals 48.0 feet long 17.0 perfs / lateral 51 perfs total <br />(1 /2 a perf means the first perf starts at the middle feed manifold) <br />7/32 inch perfs at =feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size Ft spacing, Ft pipe size on line 12, max perfs/lateral = 30 line #8 must be less - OK <br />in, =doses per day ( 4 minimum) <br />1 =gallons per dose (treatment volume) <br />2.00 5x <br />❑, 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />13) 133 feet of 2.0 inch supply line leads to F 23 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />141 173 gallons TOTAL pump out volume (treatment + drainback) <br />P29 <br />]GPM <br />feet vertical lift from pump to mound laterals, leads to a: <br />h) 24 feet of head, Pump requirement (note: -50gpm may require an extra 3-6' of head) <br />n) 500 gal Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25.49 gpi <br />Leads to a <br />18) 6.8 inch swing on Demand float, or timed dosing of6 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow)19hrs OFF test and adjust as necessary) <br />19)12]inches <br />inches from bottom of tank to "Pump OFF" float <br />'0 19inches from bottom of tank to "Pump ON" float, orP32 <br />inches to "Timer ON" f(oat if time dosed <br />'l) 22 from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed <br />22) =gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.