07-16-2018 septic design
Orono
>
Property Files
>
Street Address
>
L
>
Lillian Lane
>
2845 Lillian Lane - 33-118-23-34-0018 - New Address
>
Septic
>
07-16-2018 septic design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:51:00 PM
Creation date
8/16/2022 2:13:40 PM
Metadata
Fields
Template:
x Address Old
House Number
2845
Street Name
Lillian
Street Type
Lane
Address
2845 Lillian Lane
Document Type
Septic
PIN
3311823340018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8 <br />INSPECTOR CHECKLIST - mound <br />L845 Ltlllan Lane <br />WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10' to everything <br />(toad setback: platted: 10' prop line. Metes E bounds: out of road easement, or outer ditch. <br />LAKE/ SLUFF setback: 20' for bluff. Lakes: GD _, RD _, NE Protected wetland <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure st 10' to bed,tank Et sewer line. (else sewer line > 12" below) <br />Sewer line Et baffle connection (no 90's, 3' between 45's, slope min 1" in 8', max 2" in 8') <br />(no depth req's, clean out every 100', Sch 40 pipe) <br />Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />mfg 2250 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter Et alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />Mfg 1250 gallons <br />dose pump 36 gpm 35 head VERIFY PUMP CURVE 6.4 min Oro 9 hr OFF <br />float setting drop 9.1 inches at 25.5 gpi "DESIGNED" 5.6 inches approx float tether length <br />232.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 63,0 <br />Sand lift depth 18 inches. (Jar test: 2" sand leaves < 1/8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope <br />Bermed topsoil beyond rockbed 11 upslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe Et fittings) <br />3.0 ft lateral spacing <br />7/32 inch perforations <br />3.0 ft perforation spacing <br />17.0 downslope <br />12 sideslope 22 downslope <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary Re -use existing tank certification <br />monitoring plan and type <br />well abandonment form - if necessary <br />