My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-16-2018 septic design
Orono
>
Property Files
>
Street Address
>
L
>
Lillian Lane
>
2845 Lillian Lane - 33-118-23-34-0018 - New Address
>
Septic
>
07-16-2018 septic design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:51:00 PM
Creation date
8/16/2022 2:13:40 PM
Metadata
Fields
Template:
x Address Old
House Number
2845
Street Name
Lillian
Street Type
Lane
Address
2845 Lillian Lane
Document Type
Septic
PIN
3311823340018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 Batton Septic tank (minimum) Tank options: none <br />wx larger LanK wnn nwaupie comp) CdnKS <br />1250 gallon Dose tank (minimum) at 25.49 Bpi <br />36 GPM 35 ft. of head, Pump required <br />4.1 linch swing on Demand float which translates to roughly 5.6 inches of float tether length <br />if time dosing is required --> 6.4 minutes ON time & =hours OFF time <br />21 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />24 jinches from bottom of tank to "Hi Level Alarm" or 1 34 finches to "Hi level alarm" if time dosed <br />260 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />18 inch, or 1.5 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 61.0 ft. long 3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter ft alarm <br />F-3—]clean out & valve box assemblies <br />27.0 ft,Total sand ABSORPTION width (minimum) <br />Fft. upslope and sidestope (sand beyond rockbed, minimum) <br />93-01ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 11 ft. upstope berm <br />3:1 sidestope 12 ft. sidestope berms <br />4:1 downslope 22 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />berm 11 _t r, <br />1.5 Clean sand lift <br />_ _ 1.5 Depth to Limiting <br />Limiting Condition _____________4 <br />Absorotion Width <br />22 <br />12" cover on sides <br />(6" loamy cap & 6" sopeoil) <br />Note: <br />For 0 to 1% slopes, Absorption WIM is measured from the Bedequatty in both directions. <br />For slopes ?1%, A,bsorpt/op Wdth is measured downhill from the upslope edge of the Bed. <br />Rock Beed: 21.0 yd' or "1.4= 29 ton <br />Mound Sand: 187 yd3 or "1.4= 262 ton <br />Loamy Cap: 72 yd' or "1.4= 101 ton <br />Topsoil: 84 yd3 or *1.4= 118 ton <br />inches under pipe <br />calculation based on 3:1/4:4 slope from top of rockbe. <br />6' deep <br />6" deep <br />