My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info - 1980's
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road
>
4440 Bayside Road - 31-118-23-34-0012
>
Septic
>
Septic info - 1980's
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:31:48 PM
Creation date
9/2/2015 4:15:04 PM
Metadata
Fields
Template:
x Address Old
House Number
4440
Street Name
Bayside
Street Type
Road
Address
4440 Bayside Road
Document Type
Septic
PIN
3111823340012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
#804 - Painters Creek <br /> April 17, 1984 <br /> Page 3 <br /> Lot 6 - (Sites 14A & 14B) <br /> - Slopes at tested sites 10-15$ <br /> - Topoqraphic location OK <br /> - Site drainage OK <br /> - House siting capability - This one mig t be a problem due to location <br /> of road/cul-de-sac, drainfield site lo ation and steep slope location. <br /> Suggest a specific house site "envelop " to protect drainfield area <br /> - Reported perc rates average 19 MPI pri ary, 3 MPI alternate <br /> - Seasonal saturation zones 4 ' -6Z ' . A c rtain drain would likely be <br /> beneficial and allow trenches up to 2 ' deep <br /> Lot 7 - (Sites 15A, 15B, 7A (4/11/84) ) <br /> - Slopes at tested sites 0-lOg <br /> - Site drainage qood, topographic locati n good <br /> - Pump station likely needed due to prob ble preferred house location at high <br /> point of lot <br /> - Reported perc rates 12-16 MPI overall <br /> - Based on soil borings, the preferred si e is to the northwest just above the <br /> steep slope, where use of a curtain dr in would likely be beneficial and <br /> allow the use of shallow trenches. Th other two sites would appear <br /> to be suitable for mound systems; if a curtain drain could be installed <br /> to effectively drain this soil, shallo trenches might be possible <br /> Lot 8 - (Sites 16A, 16B, 8A (4/11/84) ) <br /> - Slope at tested sites is 6-12$ <br /> - Topographic location - above wet areas nearing base of slope <br /> - House siting should be no problem <br /> - Site drainage - may need some diversio around drainfield sites <br /> - Seasonal saturation zones reported at Z' -4 ' <br /> - Perc rates at the tested sites average 15 MPI primary, 75MPI alternate <br /> - Based on perc rates and water tables, would recommend mound systems for <br /> both sites. A shallow trench system m ght be possible at the primary <br /> site if a curtain drain effectively lo ered the water table . That may <br /> not be possible in the clayey soils pr sent <br /> 9 - (Sites 9A (4/11/84) & 9B (4/11/84) ) <br /> - Slope at tested sites 20-6� <br /> - Topographic location good <br /> - Site drainage good <br /> - House siting capability - should be '� no , problem <br /> - Perc rates average 15 MPI primary s�te 9 MPI alternate site <br /> - Saturation zones at 42-48" . Based n he information submitted, both <br /> sites are suitable for mound system$ a d may be suitable for shallow <br /> trenches if a curtain drain can be use to drain the soils <br />
The URL can be used to link to this page
Your browser does not support the video tag.