#804 - Painters Creek <br /> April 17 , 1984 <br /> Page 2 ', <br /> - Reported perc rates averaged 16 MPI rimary, 18 MPI alternate in top <br /> foot of soil <br /> - Depth to seasonal saturation zone rep rted at 4-5 . 5 ' <br /> - Soil survey indicates Kilkenny Loam a tested sites <br /> - Again, I would recommend 2 ' wide tren hes maximum, not more than 1 ' deep <br /> - A curtain drain may have some benefit, but the borings again indicate <br /> fine textured soils which resist drai age <br /> Lot 3 - (Sites 11A & 11B) <br /> - Slope at tested sites averaged 12-18$ <br />: - Topographic location - good <br /> - Site drainage appears OK <br /> - House siting capability - poor- due t road and drainfield site location , <br /> a 50 ' setback places the likely house location just above the drainfield <br /> site . I would suggest either reali�gni g the road or allowing a setback <br /> less than 50 ' to the road outlot. Bec use the sites extend the width <br /> of the lot, the shape and location of house would appear quite limited <br /> if no changes are made <br /> - Reported perc rates average 13 MPI pri ary, 23 MPI alternate at the <br /> tested site <br /> - Depth to seasonal saturation zone 4 ' -5 ' ; trench depths could possibly be <br /> 18-24" in primary site, 12" in alterna e site <br /> - Soil survey indicates Kilkenny Loam <br /> - Recommend maximum trench width 2 ' due o the slopes <br /> Lot 4 (Sites 12A & 12B) <br /> - Slope at tested sites averages 8-16� <br /> - Topographic location - OK <br /> - Site drainage - OK <br /> - House siting capability - Appears OK, ouse site establishment recommended <br /> - Reported perc rates average 33 MPI pri ary, 6 MPI alternate , in upper <br /> foot <br /> - Depth to seasonal saturation reported t 4 . 5-5 . 5 ' <br /> - Soil survey indicates Kilkenny Loam at tested sites <br /> - Trench system should be no deeper than 2 ' in primary site , 18" in alternate <br /> site , suggest trenches 2 ' wide maximum <br /> Lot 5 (Sites 13A & 13B) <br /> - Slopes at tested sites average 2-10$ <br /> - Topographic location good <br /> - Site drainage OK, note that drainfield sites for Lots 5 & 6 are adjacent <br /> - House siting capability - OK, recommen establishing a house site envelope <br /> to protect drainfield areas <br /> - Reported perc rates average 34 MPI pri ary, 20 MPI alternate <br /> - Soil borings indicate better-drainec� s ils, seasonal saturation zones <br /> below 5 ' . Trenches can be up to 2 ' de p, 3 ' wide, may need basement <br /> lift pump <br />