Laserfiche WebLink
FILE # LA21-000031 <br />17 May 2021 <br />Page 2 of 5 <br /> <br />LOT ANALYSIS WORKSHEET <br /> <br />Section 78-330 – Garage Setbacks: <br /> <br />LR-1B District Required Existing Proposed <br />Rear / Street 30’ 15.6’ 15.6’ <br />North Side 7.5’ 10.3’ 10.3’ <br />South Side 7.5’ 17.4’ 17.4’ <br />Lakeshore 75’ 181’ 191’ <br />Average Lakeshore The garage will conform to the average lakeshore setback. <br /> <br />Section 78-330 – Lot Area/Width: <br /> <br />LR-1B District Lot Area Lot Width <br />Required 43,560 s.f. (1.0 acres) 140’ <br />Actual 11,490 s.f. (0.26 acre) 50’@ 75’ / 50’ @ OHWL <br /> <br />Section 78-1403 – Structural Building Coverage: <br /> <br />Total Lot Area Total Structural Coverage <br />11,490 s.f. (0.26 acre) Allowed: 2,298 s.f. (20%) <br />Existing: 1,707 s.f. (14.8%) <br />Proposed: 1,707 s.f. (14.8%) <br /> <br />Section 78-1700 – Hardcover Calculations: <br />Until 2012, the City’s hardcover limits were based on setback zones from the lake: 0-75’ where <br />no hardcover was permitted; 75’ – 250’ zone where 25% of the lot’s area within that setback <br />zone was permitted to be hardcover; 250’ – 500’ zone where 30% of that zone’s square footage <br />was permitted to be hardcover; and 500’ -1,000’ where 35% was permitted. The previous <br />setback zones generally align with the City’s current Tier system. <br /> <br />The property received variances in 2011, including a hardcover variance to permit (32.9%) <br />hardcover in excess of 25% within the 75’ to 250’ zone. The 2011 variance resulted in a total of <br />2,608 square feet of hardcover for the property (divided between the two setback zones). The <br />applicant is not proposing changes to hardcover, however at the current level of 2,608 square <br />feet, the Tier 1 property is under the limit at 22.6%. <br /> <br />Applicable Regulations: <br />Rear Setback Variance (Section 78-330) <br />Accessory garages on lakeshore lots are permitted to be closer to the rear, street lot line than <br />the principal building when the doors on the building face away from the street – side load or <br />interior rear load. The lot width does not accommodate a side load garage. The existing garage <br />doors face the street requiring a 30-foot principal building setback. The applicant is requesting a <br />setback variance to allow a second story to be constructed over the existing garage 15 feet from <br />the rear lot line. The overall height of the garage will increase by approximately 4 feet. <br /> <br />