Laserfiche WebLink
#### <br />#### <br />CADD files prepared by the Consultant for this project are <br />instruments of the Consultant professional services for use solely <br />with respect to this project. These CADD files shall not be used <br />on other projects, for additions to this project, or for completion <br />of this project by others without written approval by the <br />Consultant. With the Consultant's approval, others may be <br />permitted to obtain copies of the CADD drawing files for <br />information and reference only. All intentional or unintentional <br />revisions, additions, or deletions to these CADD files shall be <br />made at the full risk of that party making such revisions, additions <br />or deletions and that party shall hold harmless and indemnify the <br />Consultant from any & all responsibilities, claims, and liabilities. <br />PLANNING <br />CIVIL ENGINEERING <br />LAND SURVEYING <br />LANDSCAPE ARCHITECTURE <br />ENVIRONMENTAL <br />7200 Hemlock Lane, Suite 300 <br />Maple Grove, MN 55369 <br />763.424.5505 <br />www.loucksinc.com <br />Pl <br />o <br />t <br />t <br />e <br />d <br />: <br /> <br />0 <br />6 <br /> <br />/ <br />1 <br />1 <br /> <br />/ <br /> <br />2 <br />0 <br />2 <br />1 <br /> <br /> <br /> <br />1 <br />2 <br />: <br />1 <br />9 <br /> <br />P <br />M <br />W: <br />\ <br />2 <br />0 <br />1 <br />9 <br />\ <br />1 <br />9 <br />7 <br />6 <br />7 <br />\ <br />C <br />A <br />D <br />D <br /> <br />D <br />A <br />T <br />A <br />\ <br />L <br />A <br />N <br />D <br />S <br />C <br />A <br />P <br />E <br />\ <br />_ <br />d <br />w <br />g <br /> <br />S <br />h <br />e <br />e <br />t <br /> <br />F <br />i <br />l <br />e <br />s <br />\ <br />L <br />1 <br />- <br />1 <br /> <br />L <br />a <br />n <br />d <br />s <br />c <br />a <br />p <br />e <br /> <br />P <br />l <br />a <br />n <br />OUCKSL <br />CADD QUALIFICATION <br />QUALITY CONTROL <br />PROFESSIONAL SIGNATURE <br />SUBMITTAL/REVISIONS <br />EAGLE RIDGE <br />ORONO, MINNESOTA <br />CBS MN PROPERTIES, <br />LLC <br />PO BOX 575 <br />LONG LAKE, MN 55356 <br />C1-1 EXISTING CONDITIONS PLAN <br />C1-2 DEMOLITION PLAN <br />C2-1 SITE PLAN <br />C3-1 GRADING & DRAINAGE PLAN <br />C3-2 SWPP PLAN <br />C3-3 SWPP NOTES & DETAILS <br />C4-1 UTILITY PLAN <br />C8-1 DETAIL SHEETS <br />L1-1 LANDSCAPE PLAN <br />L2-1 LANDSCAPE DETAILS <br />05-19-21 CITY SUBMITTAL <br />06-14-21 CITY COMMENTS <br />Review Date <br />SHEET INDEX <br />License No. <br />Date <br />I hereby certify that this plan, specification or report was <br />prepared by me or under my direct supervision and that <br />I am a duly Licensed Landscape Architect under the laws <br />of the State of Minnesota. <br />Gregory A. Johnson - LA <br />Project Lead <br />Drawn By <br />Checked By <br />Loucks Project No. <br />24610 <br />19767 <br />JAS <br />GAJ <br />GAJ <br />06-14-21 <br />06-14-21 <br />LANDSCAPE <br />DETAILS <br />L2-1 <br />LOUCKS <br />Deciduous Tree Planting.dwgSCALE: 1/2" = 1'-0" <br />2x ROOT BALL WIDTH <br />CONTRACTOR IS RESPONSIBLE FOR <br />TESTING PERCOLATION RATES PRIOR <br />TO PLANTING. NOTIFY LANDSCAPE <br />ARCHITECT IMMEDIATELY IF POOR <br />DRAINAGE EXISTS. <br />SET PLANT ON UNDISTURBED NATIVE <br />SOIL <br />SCARIFY BOTTOM AND SIDES OF <br />HOLE PRIOR TO PLANTING <br />EDGE VARIES - SEE PLAN <br />WOOD STAKE (OPTIONAL) <br />MULCH - 4" DEEP. NO MULCH IN <br />CONTACT WITH TRUNK - SEE NOTES <br />OR SPECS. <br />ROOT FLARE EVEN WITH OR JUST <br />ABOVE GRADE. <br />SAFETY FLAGGING - ONE PER WIRE <br />TREE WRAP TO FIRST BRANCH <br />16"x2" POLYPROPYLENE OR <br />POLYETHYLENE STRAP <br />WATER TREE THOROUGHLY DURING <br />PLANTING OPERATIONS. PLACE <br />BACKFILL IN 8-12" LIFTS AND <br />SATURATE SOIL WITH WATER. DO <br />NOT COMPACT MORE THAN <br />NECESSARY TO MAINTAIN PLUMB. <br />CUT BACK WIRE BASKET <br />PRUNE DAMAGED AND CROSSING <br />BRANCHES AFTER PLANTING IS <br />COMPLETE. <br />THE CONTRACTOR IS RESPONSIBLE <br />FOR MAINTAINING ALL TREES IN A <br />PLUMB POSITION THROUGH THE <br />WARRANTY PERIOD. STAKING IS <br />SUGGESTED, BUT NOT REQUIRED. <br />ANY STAKING MUST CONFORM WITH <br />PRACTICES AS DEFINED IN A.N.A. <br />GUIDELINES FOR STANDARD <br />PRACTICES <br />BACKFILL WITH IN SITU TOPSOIL <br />DECIDUOUS TREE PLANTING1 CONIFEROUS TREE PLANTING LOUCKS <br />Coniferous Tree Planting.dwgSCALE: 1/2" = 1'-0" <br />2 x ROOT BALL WIDTH <br />THE CONTRACTOR IS RESPONSIBLE <br />FOR MAINTAINING ALL TREES IN A <br />PLUMB POSITION THROUGH THE <br />WARRANTY PERIOD. STAKING IS <br />SUGGESTED, BUT NOT REQUIRED. <br />ANY STAKING MUST CONFORM WITH <br />PRACTICES AS DEFINED IN A.N.A. <br />GUIDELINES FOR STANDARD <br />PRACTICES. <br />PRUNE ANY DAMAGED BRANCHES <br />AFTER PLANTING IS COMPLETE. <br />16"x2" POLYPROPYLENE OR <br />POLYETHYLENE STRAP <br />SAFETY FLAGGING - ONE PER WIRE <br />BACKFILL WITH IN SITU TOPSOIL <br />WOOD STAKE (OPTIONAL) <br />EDGE VARIES - SEE PLAN <br />CONTRACTOR IS RESPONSIBLE FOR <br />TESTING PERCOLATION RATES PRIOR <br />TO PLANTING. NOTIFY LANDSCAPE <br />ARCHITECT IMMEDIATELY IF POOR <br />DRAINAGE EXISTS. <br />ROOT BALL SET ON UNDISTURBED <br />SUBGRADE <br />SCARIFY BOTTOM AND SIDES OF <br />HOLE PRIOR TO PLANTING <br />WATER TREE THOROUGHLY DURING <br />PLANTING OPERATIONS. PLACE <br />BACKFILL IN 8-12" LIFTS AND <br />SATURATE SOIL WITH WATER. DO <br />NOT COMPACT MORE THAN <br />NECESSARY TO MAINTAIN PLUMB. <br />MULCH - 4" DEEP - SEE NOTES OR <br />SPECS. MULCH MUST NOT BE IN <br />CONTACT WITH TRUNK. <br />2 <br />LANDSCAPE INSTALLATION <br />COORDINATE THE PHASES OF CONSTRUCTION AND PLANTING INSTALLATION WITH OTHER CONTRACTORS <br />WORKING ON SITE. <br />NO PLANTING WILL BE INSTALLED UNTIL COMPLETE GRADING AND CONSTRUCTION HAS BEEN COMPLETED <br />IN THE IMMEDIATE AREA. <br />WHERE SOD/SEED ABUTS PAVED SURFACES, FINISHED GRADE OF SOD/SEED SHALL BE HELD 1" BELOW <br />SURFACE ELEVATION OF TRAIL, SLAB, CURB, ETC. <br />SEED ALL AREAS DISTURBED DUE TO GRADING OTHER THAN THOSE AREAS NOTED TO RECEIVE SOD. <br />MULCH FOR TURF SEEDED AREAS SHALL BE TYPE 5 WOOD FIBER HYDROMULCH CONFORMING WITH MNDOT <br />3884. MULCH FOR SEEDED AREAS WITH SLOPES 15% OR GREATER SHALL BE MNDOT CATEGORY 1, STRAW <br />RD 1S BLANKET CONFORMING WITH MNDOT 3885. <br />SOD ALL DESIGNATED AREAS DISTURBED DUE TO GRADING. SOD SHALL BE LAID PARALLEL TO THE <br />CONTOURS AND SHALL HAVE STAGGERED JOINTS. ON SLOPES STEEPER THAN 3:1 OR IN DRAINAGE SWALES, <br />THE SOD SHALL BE STAKED TO THE GROUND. <br />ALL PLANT MATERIAL SHALL COMPLY WITH THE LATEST EDITION OF THE AMERICAN STANDARD FOR <br />NURSERY STOCK, AMERICAN ASSOCIATION OF NURSERYMEN. UNLESS NOTED OTHERWISE, ALL SHRUBS <br />SHALL HAVE AT LEAST 5 CANES AT THE SPECIFIED MINIMUM SHRUB HEIGHT OR WIDTH. ORNAMENTAL <br />TREES SHALL HAVE NO V-CROTCHES AND SHALL BEGIN BRANCHING NO LOWER THAN 3' ABOVE ROOT BALL. <br />STREET AND BOULEVARD TREES SHALL BEGIN BRANCHING NO LOWER THAN 5' ABOVE FINISHED GRADE. <br />ANY CONIFEROUS TREE PREVIOUSLY PRUNED FOR CHRISTMAS TREE SALES SHALL NOT BE USED. ALL <br />CONIFEROUS TREES SHALL BE FULL FORM, NATURAL TO THE SPECIES, WITHOUT PRUNING. <br />PLAN TAKES PRECEDENCE OVER PLANT SCHEDULE IF DISCREPANCIES IN QUANTITIES EXIST. <br />SPECIFICATIONS TAKE PRECEDENCE OVER NOTES. <br />NO PLANT MATERIAL SUBSTITUTIONS WILL BE ACCEPTED UNLESS APPROVAL IS REQUESTED OF THE <br />LANDSCAPE ARCHITECT BY THE LANDSCAPE CONTRACTOR PRIOR TO THE SUBMISSION OF A BID AND/OR <br />QUOTATION. <br />ALL PROPOSED PLANTS SHALL BE LOCATED AND STAKED AS SHOWN ON PLAN. ADJUSTMENTS IN <br />LOCATION OF PROPOSED PLANT MATERIALS MAY BE NEEDED IN FIELD. SHOULD AN ADJUSTMENT BE <br />ADVISED, THE LANDSCAPE ARCHITECT MUST BE NOTIFIED. <br />ALL PLANT MATERIALS SHALL BE FERTILIZED UPON INSTALLATION WITH A 27-3-3 SLOW RELEASE FERTILIZER <br />MIXED IN WITH THE PLANTING SOIL PER THE MANUFACTURER'S INSTRUCTIONS. PLANTS MAY BE TREATED <br />FOR SUMMER AND FALL INSTALLATION WITH AN APPLICATION OF GRANULAR 27-3-3 AT 6 OZ PER 2.5" <br />CALIPER PER TREE AND 3 OZ PER SHRUB WITH AN ADDITIONAL APPLICATION OF 27-3-3 THE FOLLOWING <br />SPRING IN THE TREE SAUCER. <br />ALL PLANTING AREAS RECEIVING GROUND COVER, PERENNIALS, ANNUALS, AND/OR VINES SHALL RECEIVE A <br />MINIMUM OF 12" DEPTH OF PLANTING SOIL CONSISTING OF AT LEAST 45 PARTS TOPSOIL, 45 PARTS PEAT <br />OR MANURE AND 10 PARTS SAND. <br />ALL PLANTS TO BE INSTALLED AS PER PLANTING DETAILS. REMOVE ALL FLAGGING AND LABELS FROM <br />PLANTS. <br />WRAPPING MATERIAL SHALL BE CORRUGATED PVC PIPING 1" GREATER IN CALIPER THAN THE TREE BEING <br />PROTECTED OR QUALITY, HEAVY, WATERPROOF CREPE PAPER MANUFACTURED FOR THIS PURPOSE. WRAP <br />ALL DECIDUOUS TREES PLANTED IN THE FALL PRIOR TO 12-1 AND REMOVE ALL WRAPPING AFTER 5-1. <br />COMMERCIAL GRADE 5" BLACK POLY EDGER TO BE USED TO CONTAIN SHRUBS, PERENNIALS, AND <br />ANNUALS WHERE BED MEETS SOD/SEED UNLESS NOTED OTHERWISE. <br />MULCH SHALL BE CLEAN SHREDDED HARDWOOD MULCH WITH UNIFORM PIECE SIZE. ALL ANNUAL AND <br />PERENNIAL BEDS TO RECIEVE 3" OF MULCH WITH NO WEED BARRIER. ALL SHRUB BED MASSINGS TO <br />RECEIVE 3" DEEP MULCH WTH A FIBER MAT WEED BARRIER. ALL TREES NOT IN PLANTING BEDS TO RECEIVE <br />4" DEEP MULCH WITH NO MULCH IN DIRECT CONTACT WITH TREE TRUNK. <br />SPREAD GRANULAR PRE EMERGENT HERBICIDE (PREEN OR EQUAL) PER MANUFACTURER'S <br />RECOMMENDATIONS UNDER ALL MULCHED AREAS. <br />MAINTENANCE STRIPS TO HAVE EDGER AND MULCH AS SPECIFIED/INDICATED ON DRAWING OR IN <br />SPECIFICATION. <br />ROCK MULCH SHALL BE 1"-1-1/2" GREY TRAP ROCK, 4" DEEP OVER A FIBER MAT WEED BARRIER. <br />IF THE LANDSCAPE CONTRACTOR IS CONCERNED OR PERCEIVES ANY DEFICIENCIES IN THE PLANT <br />SELECTIONS, SOIL CONDITIONS OR ANY OTHER SITE CONDITION WHICH MIGHT NEGATIVELY AFFECT PLANT <br />ESTABLISHMENT, SURVIVAL OR GUARANTEE, HE MUST BRING THESE DEFICIENCIES TO THE ATTENTION OF <br />THE LANDSCAPE ARCHITECT PRIOR TO PROCUREMENT AND/OR INSTALLATION. <br />CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR THE OWNER ACCEPTANCE INSPECTION OF ALL <br />LANDSCAPE AND SITE IMPROVEMENTS. <br />CONTRACTOR IS RESPONSIBLE FOR ON-GOING MAINTENANCE OF ALL NEWLY INSTALLED MATERIALS UNTIL <br />TIME OF OWNER ACCEPTANCE. ANY ACTS OF VANDALISM OR DAMAGE WHICH MAY OCCUR PRIOR TO <br />OWNER ACCEPTANCE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL PROVIDE <br />THE OWNER WITH A MAINTENANCE PROGRAM INCLUDING, BUT NOT NECESSARILY LIMITED TO, PRUNING, <br />FERTILIZATION AND DISEASE/PEST CONTROL. <br />CONTRACTOR SHALL WARRANTY NEW PLANT MATERIAL THROUGH ONE CALENDAR YEAR. WARRANTY <br />SHALL BEGIN ON THE DATE OF ACCEPTANCE BY THE LANDSCAPE ARCHITECT AFTER THE COMPLETION OF <br />PLANTING OF ALL LANDSCAPE MATERIALS. NO PARTIAL ACCEPTANCE WILL BE CONSIDERED. <br />UNLESS NOTED OTHERWISE THE APPROPRIATE DATES FOR SPRING PLANT MATERIAL INSTALLATION AND <br />SEED/SOD PLACEMENT IS FROM THE TIME GROUND HAS THAWED TO JUNE 15. <br />FALL SODDING IS GENERALLY ACCEPTABLE FROM AUGUST 15 - NOVEMBER 1. FALL SEEDING FROM AUGUST <br />15 - SEPTEMBER 15; DORMANT SEEDING IN THE FALL SHALL NOT OCCUR PRIOR TO NOVEMBER 1. FALL <br />CONIFEROUS PLANTING MAY OCCUR FROM AUGUST 15 - OCTOBER 1 AND DECIDUOUS PLANTING FROM <br />THE FIRST FROST UNTIL NOVEMBER 15. PLANTING OUTSIDE THESE DATES IS NOT RECOMMENDED. ANY <br />ADJUSTMENT MUST BE APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT. <br />LANDSCAPE CONTRACTOR SHALL ESTABLISH TO HIS SATISFACTION THAT SOIL AND COMPACTION <br />CONDITIONS ARE ADEQUATE TO ALLOW FOR PROPER DRAINAGE AT AND AROUND THE BUILDING SITE. <br />VARIES <br />SEE PLAN <br />EDGING MATERIAL - SEE NOTES <br />EDGE VARIES - REFER TO PLAN <br />MULCH - 3" MIN DEPTH - SEE NOTES <br />LOOSEN ROOTS OF PLANT MATERIAL <br />PRIOR TO PLANTING <br />12" DEPTH (MIN) LOAM PLANTING SOIL - <br />SEE NOTES <br />PERENNIAL PLANTING LOUCKS <br />Perennial Planting.dwgSCALE: 3/4" = 1'-0" <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />W <br />A <br />L <br />L <br /> <br />( <br />T <br />Y <br />P <br />) <br />4 <br />REFER TO PLAN <br />18" MIN. <br />SHRUBS TO BE PLACED SO THAT TOP OF <br />CONTAINER SITS FLUSH WITH PROPOSED GRADE. <br />MULCH - 3" DEPTH - SEE NOTES OR SPEC. <br />LANDSCAPE FABRIC - SEE NOTES OR SPEC. <br />EDGING MATERIAL - SEE NOTES OR SPEC. <br />EDGE VARIES - REFER TO PLAN <br />PLANTING SOIL - SEE NOTES OR SPEC. <br />LOOSEN ROOTS OF ALL CONTAINERIZED PLANTS. <br />SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO <br />PLANTING <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />W <br />A <br />L <br />L <br /> <br />( <br />T <br />Y <br />P <br />) <br />SHRUB PLANTING LOUCKS <br />Shrub Planting.dwgSCALE: 3/4" = 1'-0"3 <br />42" ORNAMENTAL FENCE - DELGARD LOUCKS <br />42INCH ORN FENCE - DELGARD.dwgSCALE: 3/8" = 1'-0" <br />2" SQUARE FENCE POST <br />3' <br />- <br />8 <br />" <br />6'-3/4" <br />4" <br />6" <br />1' <br />- <br />6 <br />" <br />3" <br />MODEL: 42" ELBA RESIDENTIAL FENCE BY DELGARD (OR EQUAL) <br />COLOR: BLACK <br />1-800-235-0185 WWW.DELGARD.COM <br />1" X 1" TOP AND MID RAIL <br />5/8" X 5/8" PICKET <br />1" X 1" BOTTOM RAIL <br />GRADE <br />EXISTING SUBGRADE <br />CONCRETE FOOTING <br />5