Laserfiche WebLink
BONESTROO AND ASSOC SP 6516361311 10/10/01 07:17 5 :01/03 N0:921 <br /> Bonestroo,Roaene,AnderIlk and Associates,Inc.Is an Affirmative Actlun/Equal Opportunity Employer <br /> Bonestroo and Employee Owned <br /> Principals:Olio C.OuntesLruu,P.C..Marvin L.SOrval.a,P.C.• Clervi R.COLA,RE.. Rarer(C.SL 1unic.ltI PF. <br /> Rosene Jerry A.Bourdon,P.C. <br /> Anderlik & Senior Consultants:Ruttert W.Ru.+uric,,RC.• Juheeph C.Andurlik,PC.. Richard C.Turner,P.C.. Su1.,n M.Pberlin,C.P.A. <br /> Associate Principals:Keith A.(iurclnn, PF.• RuUrrI R.Pfril'rrlr• PF.• i(it tr,ud W.Fader,RF.•D.rvid Q I ntknl.l,P{: <br /> Associates M,ek A.!Limon.P.F.•Mu heel I.ILuadnann,P.F.• Ted K.Held,PE.. krnnrtn P Anthu,wn,PP.• Mirk Rolf%,P.F.• <br /> David A.Ounraruu,M.O.A.• Sidney f Willi;ansae,PC.,L.S.• Ac{nes M.Riny,M.O.A.•Allan Rick St.hrnidt,P.E.. <br /> Thonv,t W.Peterson,PE.• lamer(R.Mnlanr.l,P.C. Milch R. lernsan,PE.• L.Phillip Gravel III,PC.• Daniel.1.Edgerton,P.F.• <br /> Engineers &Architects <br /> Ivndr•I M,nlinrr.PF • Thomas.A Syfkn,PF • Sheldon I lahnton• Dalt-A Grove,PF . Thrinl,lt A Curnhitr.PF • <br /> /� <br /> Robert J.()every.Pat. <br /> October 9, 2001 Offices:SI.Paul,St.Cloud,RurJlenter avid Willmar,MN• Milwaukee,WI• Chicago,IL <br /> Wepsltr:www hrvi CSrrnn rum <br /> Mr. Michael P. Gaffron, <br /> Senior Planning Coordinator <br /> City of Orono <br /> Post Office Box 66 <br /> Crystal Bay, Minnesota 55323 <br /> Re: Orono Senior Housing <br /> File No. 139-01-000 <br /> Plat No. 2641 <br /> Dear Mike, <br /> We have reviewed the site plans for the proposed Orono Woods Apartments. The site is located in the <br /> northwest quadrant of Wayzata Boulevard (T.H. 12) and North Brown Road. The site is proposed to be <br /> developed as a senior housing complex and office building. The plans show the senior housing to be <br /> constructed as Phase 1 and the office complex as Phase 2. It is our understanding that the use for Phase 2 may <br /> change based on demand.This review focuses primarily on Phase 1.The following are comments with regards <br /> to engineering matters: <br /> 1. Traffic: The proposed layout appears to be in accordance with our traffic flow comments dated <br /> November 14, 2000. We recommend that the access onto Wayzata Boulevard be signed and striped as a <br /> right-in right-out only intersection. MnDOT should comment on the construction or striping of a <br /> westbound right turn lane into the site from T.H. 12.Cross walk sniping and traffic control signing will <br /> be necessary at various locations within the site. Signing and striping plans should be included with the <br /> plan set. Streets and parking areas should he constructed to the City's commercial/industrial street section <br /> as per City Standard Detail STR-7. All streets and parking areas shall have B618 concrete curb and <br /> gutter. <br /> 2. Grading:The grading plan shows street grades at both accesses ranging between 5% and 6%.This will <br /> create problems for stopping and turning movements, particularly in the winter. We recommend a <br /> minimum landing area of 50 feet with a maximum grade of 2%at both accesses.Some parking lot grades <br /> are shown at 5%. We would recommend that parking lot grades not exceed 4 percent.The grades on the <br /> access road to the office complex exceed 8%. Grades to the parking area for the office complex are <br /> shown at 10%.We recommend these grades be reduced as much as practical for the stopping and turning <br /> reasons noted above.The proposed retaining wall northwest of the pond is 8-feet tall at its highest point, <br /> all retaining walls over 4-feet in height require an engineered design and details.All silt fence must be in <br /> place prior to any grading activity. <br /> 3. Drainage: A drainage area map and storm sewer calculations should be provided for our review. Plans <br /> should he submitted to the Minnehaha Creek Watershed District for their review.MnDOT should review <br /> and comment on the plans and provide verification that the existing pond is sized for the proposed <br /> developed conditions.inverts of flared end sections(FES)outletting to the pond should be set at the pond <br /> normal water level (NWL) of 972.0 +/-. Class 111 riprap should be called out and quantified at all FES. <br /> Minimum storm sewer size shall be 12-inches. All storm sewer in the roadway or parking areas shall he <br /> RCP. <br />