09-12-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road
>
4465 Bayside Road - 06-117-23-21-0006
>
Septic
>
09-12-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:24:29 PM
Creation date
10/5/2021 12:56:37 PM
Metadata
Fields
Template:
x Address Old
House Number
4465
Street Name
Bayside
Street Type
Road
Address
4465 Bayside Rd
Document Type
Septic
PIN
0611723210006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4465 Bdysltle Ko., Drono INSPECTOR CHECKLIST - mound <br />WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 111- to dispersal area with shallow wait <br />PROPERTY LINES setback: IV to everything <br />Road setback: platted: 10' prop line. Metes 8 bounds: out of road easement, or outer ditch. <br />LAKE / BLUFF setback: 20' for bluff. Lakes: GD _, RD _, NE — Protected wetland _ <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure sc 10' to bed,tank 8 sewer line. (else sewer line > 12" below) <br />Sewer line & baffle connection (no 9Vs, T between 45's, slope min 1" m 8', max 2" in 8') <br />(no depth reqs, clean out every 100', Sch 40 pipe) <br />Septic tank and risen (water tight, insulated, proper depth, existing verified by pumping) <br />Mfg 1500 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter 8 alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />mfq 1250 gallons <br />dose pump 38 gpm 30 head VERIFY PUMP CURVE 4.9 min ON 9 hr OFF <br />float setting drop 7.2 inches at 26.0 gpi "DESIGNED" 4.6 inches approx float tether length <br />186.0 gal dose divided by gpi "INSTALLED" = _inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: SCh40, sloped 1/8"., supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control pane( / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 50.0 <br />Sand lift depth 14 inches. (Jar test : 2- sand leaves < 1/8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope 17.0 downslope <br />❑ Bermed topsoit beyond rockbed 10 upslope 16 sideslope 23 downslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe 8 fittings) <br />3.0 ft lateral spacing <br />e 1/4" inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary =Re -use existing tank certification <br />monitoring plan and type <br />wet( abandonment form - if necessary <br />