09-12-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road
>
4465 Bayside Road - 06-117-23-21-0006
>
Septic
>
09-12-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:24:29 PM
Creation date
10/5/2021 12:56:37 PM
Metadata
Fields
Template:
x Address Old
House Number
4465
Street Name
Bayside
Street Type
Road
Address
4465 Bayside Rd
Document Type
Septic
PIN
0611723210006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />1500 Igattn Septic tank (minimum) Tank options: none <br />1250 gallon Dose tank (minimum) at 26.00 gpi <br />38 GPM 30 ft. of head, Pump required <br />7.1 inch swing on Demand float which translates to roughly 4.6 inches of float tether length <br />if time dosing is required -->4.9 minutes ON time Et =9 hours Orf time <br />19 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />22 1 inches from bottom of tank to "Hi Level Alarm" or 32 inches to "Hi level alarm" if time dosed <br />210 ft. of F2.071nch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />14 inch, or 1.2 ft. Sand Lift Mound <br />10.0 ft. wide by 50.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 48.0 ft. long 3.0 ft. lateral spacing <br />1/4" inch perfs 1 3.0 Ift. perforation spacing <br />No Effluent filter ft alarm <br />3 clean out Et valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 10 ft. upslope berm <br />4:1 sideslope16 ft. sideslope berms <br />4:1 downslope 1 23 Ift. downslope berm <br />inspection pipe <br />—18" cover on top <br />12" cover an sides <br />(6"loamy cap & 6"topsoil) <br />1.2 Clean sand lift <br />lDeptL8 <br />h to Llmitinv <br />Note: <br />For 0 to 1% slopes, absorption Width is measured from the BedequaLly in loth directions. <br />For slopes 11%, absorption Wdtbis measured downhill from the upslope edge of the Bed. <br />Rock Bed: A7yd <br />yd'or'1.4= 32 ton 9 inches under pipe <br />Mound Sand: yd' or "1.4= 223 to <br />calculation based on 3:1/4:1 slope from top of rockbe <br />Loamy Cap: yds or *1.4= 95 ton 6" deep <br />Topsoil: s or'1.4= 111 ton 6" deep <br />