My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
05-02-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
W
>
West Farm Road
>
1860 West Farm Road - 27-118-23-43-0018
>
Septic
>
05-02-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:38 PM
Creation date
10/1/2021 4:18:44 PM
Metadata
Fields
Template:
x Address Old
House Number
1860
Street Name
West Farm
Street Type
Road
Address
1860 West Farm Road
Document Type
Septic
PIN
2711823430018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />1500 gallon Septic tank (minimum) Tank options: none <br />oux Larger rank warn muiripie camp/ranks <br />1000 gallon Dose tank (minimum) at 25.00 gpi <br />38 GPM @ 33 ft. of head, Pump required <br />7.4 linch swing on Demand float which translates to roughly 4.7 inches of float tether length <br />if time dosing is required -->F 4.8 minutes ON time Ft ®hours OFF time <br />19 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />22 inches from bottom of tank to "Hi Level Alarm" or 32 inches to "Hi level alarm" if time dosed <br />200 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />20 inch, or 1.7 ft. Sand Lift Mound <br />10.0 ft. wide by 12.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 10.0 ft. long 3.0 ft. lateral spacing <br />1/4" inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Ft alarm <br />3 clean out 8t valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 12 ft. upslope berm <br />3:1 sideslope 1 13 Ift. sideslope berms <br />4:1 downslope 1 21 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />UDS100e berm 12 _1 � 1 _ nnurncinnc knrm <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />1.7 11 dean sand lift <br />1.3 Depth to Limiting <br />i_irntting i~ondition _ "_`4—__- — -u <br />Absorption Width 27.0 <br />Note: <br />For 4 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1`Yo, Ahsorption 1Hidthis measured downhill from the upslope edge of the Bed. <br />Rock Bed: 4.0 yd3 or *1.4= 6 ton <br />Mound Sand: 73 yd or *1.4= 102 ton <br />Loamy Cap: 30 yd or *1.4= 42 ton <br />Topsoil: 37 yd or *1.4= 52 ton <br />6 inches under pipe <br />calculation based on 3:1/4.-1 slope from top of rockbet <br />6" deep <br />6" deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.