My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
05-02-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
W
>
West Farm Road
>
1860 West Farm Road - 27-118-23-43-0018
>
Septic
>
05-02-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:38 PM
Creation date
10/1/2021 4:18:44 PM
Metadata
Fields
Template:
x Address Old
House Number
1860
Street Name
West Farm
Street Type
Road
Address
1860 West Farm Road
Document Type
Septic
PIN
2711823430018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br />www.SepticResource.com (vers 15.2) <br />Property Owner: Mark Beltrand Date: 11/12/2018 <br />Site Address: 1860 West Farm Road PID: 2711823430018 <br />Comments: Add 1 bedroom to a 3 bedroom mound <br />instructions: E71 = enter data = adjust if desired = computer calculated - DO NOT CHANGE! <br />1)bedroom Type �I Residential System <br />2) 340 GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />4) 1500 Gal Septic tank (code minimum) 1500 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />s) 1.2 GPD/ft2 mound sand loading rate contour loading rate of F 12 req's a min 38 ft. long rockbed <br />C) 10.0 Ift rockbed width 12.0 ft rockbed length <br />7) 3.0 ft lateral spacing 3.4 ft perforation spacing (maximum of 3 for both) <br />Lend feed manifold connection <br />8) laterals 10.0 feet long 4.0 perfs / lateral 12 perfs total <br />(1 /2 a perf means the first perf starts at the middle feed manifold) <br />9) 1 /4" inch perfs at feet residual head gives 0.74 gpm flow rate per perforation <br />for this perf size Et spacing, Et pipe size on line 12, max perfs/lateral = 25 , line #8 must be less — OK <br />101 4.0 doses per day (4 minimum) <br />11) 75 gallons per dose (treatment volume) <br />2.00 5x <br />12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />13) 200 feet of 2.0 inch supply line leads to34 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 184 gallons TOTAL pump out volume (treatment + drainback) <br />15) 18 feet vertical lift from pump to mound laterals, leads to a: <br />16) 38 GPM @ 33 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 500 gal Dose tank (code minimum) 1000 gal Dose tank (design size / LUG req'd) at 25.00 gpi <br />leads to a <br />18) 7.4 inch swing on Demand float, or timed dosing of4.8 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow)Mhrs OFF test and adjust as necessary) <br />19) 12 inches from bottom of tank to "Pump OFF" float <br />20) 19 inches from bottom of tank to "Pump ON" float, or 12 inches to "Timer ON" float if time dosed <br />21) 22 inches from bottom of tank to "Hi Level" float, or 32 inches to "Hi Level" float if time dosed <br />22) 450 gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.