10-30-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
H
>
Hunter Drive
>
1130 Hunter Drive- 25-118-23-42-0007 (Formerally 300 Sixth Ave N)
>
Septic
>
10-30-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:14 PM
Creation date
10/1/2021 2:29:48 PM
Metadata
Fields
Template:
x Address Old
House Number
1130
Street Name
Hunter
Street Type
Drive
Address
1130 Hunter Drive
Document Type
Septic
PIN
2511823420007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
it v.7 I1 L. uownstope <br />Individual slope ratios give BERM widths (topsoil beyond rockbed) of: <br />Nr 4:1 upslope ratioItft. <br />ft, upslope berm <br />a 3:1 sideslope ft. sideslope berms <br />4:1 downslope downslope berm <br />>> Overall Dimensions: 9.9 ft. wide by 63.0 ft. long Rock bed <br />43 ft. wide by L_87A ft. long Mound footprint <br />4) <br />4" inspection pipe <br />18" cover on top <br />Upslope berm =_l 1� I. <br />1.5 11 Clean sand lift <br />Doi^rms63pe berm 22 <br />12" cover on sides <br />(d" loamy cap &.6" topsoil) <br />_ __ 1.5 Depth to Limiting <br />Limiting Condition — — — — — — — — — — — — — — — <br />Absorption Width26.8 ---`---- — — z —.- <br />Note: _ <br />For 0 to 1% slopes, Absorption Width is measured from the Beo equalty in both directions. <br />For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed <br />Rock Bed: <br />9.9 ft. by 63.0 ft. by inches under pipe, plus 20% gives =yd' or *1.4= 29 ton <br />Mound Sand: (note: volume is based on 3:1/4:1 slope from top of rockbed, Exchange sand for loamy cap if desired) <br />29.5 up +73.7 downslope + 10.6 ends + 41.6 under rock =F-1 87 yd' or *1.4= F 261 ton <br />plus 20% <br />5) Loamy Cap: <br />39 ft. by =ft. 6" deep, plus 20% gives <br />5) Topsoil: <br />43 ft. by 87 ft. 6" deep, plus 20% gives <br />72 yd' or *1.4= 101 ton <br />83 yd' or*1.4= =ton <br />I hereby certify that 1 have completed this work in accordance with all applicable ordinances, rules and laws. <br />Rusty Olson"s Soil & Perc 810 2/19/2018 <br />signer Signature Company License# Date <br />Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />ouzo iafger tanK wiut muttipte cumpf tarns <br />1300 gallon Dose tank (minimum) at 25.49 gpi <br />36 GPM E20 ft. of head, Pump required <br />=inch swing on Demand float which translates to roughly 4.9 inches of float tether length <br />if time dosing is required --> 5.5 minutes ON time Et =hours OFF time <br />20 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />23 linches from bottom of tank to "Hi Level Alarm" or 33 inches to "Hi level alarm" if time dosed <br />60 ft. of =inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />