instructions: = = enter data t = adjust if desired 0 = computer calculated - DO NOT CHANGE! <br />I t =bedroorn Type �I Residential System <br />3) 750 GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size /LUG req'd) <br />Tank options: none <br />s) 1.2 GPD/ftz mound sand loading rate contour loading rate of =req's a min 63 ft. long rockbed <br />6) =ft rockbed width 63.0 ft rockbed length <br />7) =ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />S) I (laterals 61.0 feet tong 21.0 perfs / lateral F 63 perfs total <br />(1 /2 a perf means the first perf starts at the middle feed manifold) <br />3i 7/32 inch perfs at =feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size ft spacing, Et pipe size on line 12, max perfs/lateral = 30 line #8 must be less --> OK <br />io) =doses per day (4 minimum) <br />i 1 t 188 gallons per dose (treatment volume) <br />2.00 5x <br />12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />3t 60 feet of 2.0 inch supply line leads to 10 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />4) F198 gallons TOTAL pump out volume (treatment + drainback) <br />t5) F3�6GPM <br />feet vertical lift pump to mound laterals, leads to a: <br />t6) C� 20 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 750 gal Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25,49 gpi <br />leads to a <br />tat =inch swing on Demand float, or timed dosing of5.5 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow)hrs OFF test and adjust as necessary) <br />t9)Itinches <br />inches from bottom of tank to "Pump OFF" float <br />20) inches from bottom of tank to "Pump ON" float, or 12 inches to "Timer ON" float if time dosed <br />21) from bottom of tank to "Hi Level" float, or 33 inches to "Hi Level" float if time dosed <br />22)714 gatlons reserve capacity (after High Level Alarm is activated) <br />0.45 gpd/ftz Absorption area Soil Loading Rate, which gives a mound ratio of2.7 (minimum) <br />(this must match the soil boring log) desired mound ratio 2.7 <br />=percent site slope (0-20% range) = (% downslope site slope, if different than upslope) <br />18 3riches, or 1.5 ft. to Redox or other limiting condition (need at least 12" to be a Type 1) <br />Treatment zone contains inches of 0% soil credit, and F 701nches of 50% soil credit. Giving a: <br />=inch, or 1.5 ft. Sand Lift Mound CRITICAL FOR FUTURE CERTIFICATIONS!!! <br />26.$ ft.Total ABSORPTION width (with sand beyond rockbed as follows:) <br />0.0 ft. upslope and sideslope <br />