My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-20-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0315 Old Crystal Bay Road North - 33-118-23-31-0004
>
Septic
>
07-20-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:49:14 PM
Creation date
10/1/2021 1:43:32 PM
Metadata
Fields
Template:
x Address Old
House Number
315
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
315 Old Crystal Bay Road North
Document Type
Septic
PIN
3311823310004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br />315 Uld Crystal bay Koad N. <br />WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes Et bounds: out of road easement, or outer ditch. <br />LAKE/ BLUFF setback: 20' for bluff. Lakes: GD —, RD _, NE protected wetland _ <br />Building, setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure sc 10' to bed,tank Et sewer line. (else sewer line > 12" below) <br />FjSewer line ix baffle connection (no 90's, 3' between 45's, slope min 1" in 8', max 2" in 8') <br />(no depth reqs, clean out every 100', Sch 40 pipe) <br />ElSeptic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />mfg 2250 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter & alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />Mfg 1250 gallons <br />dose pump 29 gpm 24 head VERIFY PUMP CURVE 6.7 min ON 9 hr OFF <br />float setting drop 7.7 inches at 25.5 gpi "DESIGNED" 4.9 inches approx float tether length <br />195.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 50.0 <br />Sand lift depth 20 inches. (Jar test : 2" sand leaves < 1 /8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope <br />Bermed topsoil beyond rockbed 12 upslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe ft fittings) <br />3.0 ft lateral spacing <br />7/32 inch perforations <br />3.0 ft perforation spacing <br />17.0 downslope <br />17 sideslope 20 downslope <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary <br />monitoring plan and type <br />well abandonment form - if necessary <br />�Re-use existing tank certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.