My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-20-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0315 Old Crystal Bay Road North - 33-118-23-31-0004
>
Septic
>
07-20-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:49:14 PM
Creation date
10/1/2021 1:43:32 PM
Metadata
Fields
Template:
x Address Old
House Number
315
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
315 Old Crystal Bay Road North
Document Type
Septic
PIN
3311823310004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />au7a Larger LdnK WIM rnuuipre comer LanKs <br />1250 gallon Dose tank (minimum) at 25.49 gpi <br />29 GPM ft. of head, Pump required <br />7.7 inch swing on Demand float which translates to roughly 49 inches of float tether length <br />if time dosing is required -->6.7 minutes ON time $ ®hours OFF time <br />20 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />23 inches from bottom of tank to "Hi Level Alarm" or 33 inches to "Hi level alarm" if time dosed <br />265 ft. of 2.0 inch supply Eine with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />20 inch, or 1.7 ft. Sand Lift Mound <br />10.0 ft. wide by 50.0 ft. tong Rock bed <br />3 laterals 2.00 inch diameter 48.0 ft. long F 3.p ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter if alarm <br />3 clean out ix valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0- 07 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratioT]17� <br />ft. upslope berm <br />4:1 sideslope ft. sideslope berms <br />4:1 downslope ft. downslope berm <br />berm 1z <br />MA <br />1.3 <br />1-imititig Condition `- <br />4" inspection pipe <br />r— 18" cover can top <br />12"' cover can sides <br />(6" loamy cap & 6" topsoil) <br />Clean sand lift <br />Depth to Limiting <br />---- <br />Absorption Width—�— ,— - <br />Note: <br />For 0 to 1" slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1, Absorption Width is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 17.0 yd3 or *1.4= 24 ton <br />Mound Sand: 185 yd3 or *1.4= 259 ton <br />Loamy Cap: 68 yd3 or *1.4m 95 ton <br />Topsoil: 79 yd3 or *1.4= 111 ton <br />inches under pipe <br />calculation based on 3:1 /4:1 slope from top of rockbe, <br />6" deep <br />6" deep <br />