07-04-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
F
>
Fox St
>
3345 Fox St - 05-117-23-44-0007
>
Septic
>
07-04-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:22:30 PM
Creation date
9/30/2021 4:16:50 PM
Metadata
Fields
Template:
Address
House Number
3345
Street Name
Fox
Street Type
Street
Address
3345 Fox St
Document Type
Septic
PIN
0511723440007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />3000 gallon Septic tank (minimum) Tank options: none <br />owb Barger LanK wi[,n rnuuiple cramp/ Lan KS <br />1500 gallon Dose tank (minimum) at 29.41 gpi <br />49 GPM @ 42 ft. of head, Pump required <br />10.7 inch swing on Demand float which translates to roughly 6.4 inches of float tether length <br />if time dosing is required - >6.4 minutes ON time Et =hours OFF time <br />23 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />26 inches from bottom of tank to "Hi Level Alarm" or 1 36 linches to "Hi level alarm" if time dosed <br />305 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />20 inch, or 1.7 ft. Sand Lift Mound <br />10.0 ft. wide by 88.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 86.0 ft. long 3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing. <br />No Effluent filter Et alarm <br />3 Iclean out a valve box assemblies <br />27,0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 11 ft. upslope berm <br />3:1 sideslope 13 ft. sideslope berms <br />4:1 downslope <br />a 31 ft. downslope berm <br />Upslope berm 11 <br />t 1.7 <br />1.3 <br />Lim:ttir39 Conditic <br />4" inspection pipe <br />r- 18" cover on top <br />Clean sand lift <br />Depth to Limiting <br />-------------- <br />Absorption Width 27 <br />31 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />Note: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1 %, Absorption Wdth is measured downhill from the upslope edge of the Beat <br />Rock Bed: 30.0 yd or*1.4= 42 ton <br />Mound Sand: 337 yd3 or *1.4= 472 ton <br />Loamy Cap: 118 yd or *1.4= 165 ton <br />Topsoil: 132 yd or *1.4= 185 ton <br />inches under pipe <br />calculation based on 3:1/4:1 slope from top of rockbe, <br />6" deep <br />6" deep <br />