My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-14-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
750 Big Island - PID: 23-117-23-22-0009
>
Septic
>
06-14-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:12:30 PM
Creation date
9/29/2021 8:57:53 AM
Metadata
Fields
Template:
x Address Old
House Number
750
Street Name
Big Island
Address
750 Big Island
Document Type
Septic
PIN
2311723220009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Pump Tank Design Worksheet UNIVERSITY <br />&*� Minnesota Pollution (Demand Dose) OF MINNESOTA <br />Control Agency <br />DETERMINE TANK CAPACITY AND DIMENSIONS <br />Pipe <br />Diameter <br />(inches) <br />Project ID: 071420175oiIIDA v 04,06.2017 <br />1. A. <br />Design Flow: <br />225 GPD <br />0.078 <br />B. <br />Min. required pump tank capacity: <br />0.110 Gallons/ft <br />500 <br />Gal <br />C.Recommended pump tank capacity: <br />500 Gal <br />2. A. <br />Tank Manufacturer: <br />Norwesco <br />B. <br />Tank Model: 500 Gallon Sphere Pum <br />10. Minimum Alarm Volume = Depth of alarm (2 or 3 inches) X gallons <br />C. <br />Capacity from manufacturer: <br />�in X 12.5 gal/in = <br />500 <br />Gallons <br />Note: Design calculations are based on this specific tank. <br />Substituting a different tank model will change the pump <br />float or timer settings. Contact designer if changes are <br />D. <br />Gallons per inch from manufacturer: <br />1.2.5 <br />Gallons <br />per inch necessary. <br />E. <br />Liquid depth of tank from manufacturer: <br />40.0 inches <br />DETERMINE DOSING VOLUME <br />3 Calculate Volume to Cover Pump (The inlet of the pump must be at least 4 -inches from the bottom of the pump tank It 2 inches of water covering the pump is <br />recommended) <br />(Pump and block height + 2 inches) X Gallons Per Inch (2C or 3E) <br />( 12 in + 2 inches) X 12.5 Gallons Per Inch <br />4 Minimum Delivered Volume = 4 X Volume of Distribution Piping: <br />- Line 17 of the Pressure Distribution or Line 1 f of Non -level <br />5 Calculate Maximum Pumpout Volume (25% of Design Flow) <br />Design Flaw: 225 GPD X <br />6 Select a pumpout volume that meets both Minimum and Maximum: <br />7 Calculate Doses Per Day = Design Flow : Delivered Volume <br />225 gpd 45 gat = <br />8 Calculate Drainback: <br />0.25 - <br />45 Gallons <br />5.00 Doses <br />DEMAND DOSE FLOAT SETTINGS <br />11. Calculate Float Separation Distance using Dosing Volume. <br />Total Dosing Volume /Gallons Per Inch <br />48 gal : 12.5 gal/in = 3.9 Inches <br />12. Measuring from bottom of tank: <br />A. Distance to set Pump Off Float = Pump + block height + 2 inches <br />12 in + O in 14 Inches <br />B. Distance to set Pump On Float=Distance to Set Pump -Off Float + Float Separation Distance <br />14 in + 3.9 in = 98 Inches <br />C. Distance to set Alarm Float = Distance to set Pump -On Float + Alarm Depth (2-3 inches) <br />16 in + 2.0 in = 20 Inches <br />175 Gallons <br />37 Gallons (minimum dose) <br />Sb Gallons (maximum dose) <br />Volume of Liquid in <br />Pipe <br />Pipe <br />Diameter <br />(inches) <br />A. Diameter of Supply Pipe= <br />1.5 inches <br />B. Length of Supply Pipe = <br />30 feet <br />0.078 <br />1.5 <br />C. Volume of Liquid Per Lineal Foot of Pipe = <br />0.110 Gallons/ft <br />D. Drainback = Length of Supply Pipe X Volume of Liquid Per Lineal Foot of Pipe <br />30 ft X 0.110 gal/ft = <br />3.3 Gallons <br />9, Total Dosing Volume = Delivered Volume plus Drainback <br />0.661 <br />45 gal + 3.3 gat = <br />48 <br />Gallons <br />10. Minimum Alarm Volume = Depth of alarm (2 or 3 inches) X gallons <br />per inch of tank <br />�in X 12.5 gal/in = <br />25.0 Gallons <br />DEMAND DOSE FLOAT SETTINGS <br />11. Calculate Float Separation Distance using Dosing Volume. <br />Total Dosing Volume /Gallons Per Inch <br />48 gal : 12.5 gal/in = 3.9 Inches <br />12. Measuring from bottom of tank: <br />A. Distance to set Pump Off Float = Pump + block height + 2 inches <br />12 in + O in 14 Inches <br />B. Distance to set Pump On Float=Distance to Set Pump -Off Float + Float Separation Distance <br />14 in + 3.9 in = 98 Inches <br />C. Distance to set Alarm Float = Distance to set Pump -On Float + Alarm Depth (2-3 inches) <br />16 in + 2.0 in = 20 Inches <br />175 Gallons <br />37 Gallons (minimum dose) <br />Sb Gallons (maximum dose) <br />Volume of Liquid in <br />Pipe <br />Pipe <br />Diameter <br />(inches) <br />Liquid <br />Per Foot <br />(Gallons) <br />1 <br />0.045 <br />1.25 <br />0.078 <br />1.5 <br />0.110 <br />2 <br />0.170 <br />3 <br />0.380 <br />4 <br />0.661 <br />Inches for Dose: 3.9 in <br />Alarm Depth <br />19.9 in <br />Pump On <br />17.9 in <br />25.0 Gal <br />Pump Off <br />14.0 in <br />48 Gal <br />f75 Gal <br />
The URL can be used to link to this page
Your browser does not support the video tag.