My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-14-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
750 Big Island - PID: 23-117-23-22-0009
>
Septic
>
06-14-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:12:30 PM
Creation date
9/29/2021 8:57:53 AM
Metadata
Fields
Template:
x Address Old
House Number
750
Street Name
Big Island
Address
750 Big Island
Document Type
Septic
PIN
2311723220009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Basic Pump Selection <br />UNIVERSITY <br />Minnesota Pollution Desien Worksheet OF MINNESOTA <br />lonxroi Agency <br />1. PUMP CAPACITY Project ID: 071420175oilIDA v 04.06.2017 <br />Pumping to Gravity or Pressure Distribution: Pressure <br />1. If pumping to gravity enter the gallon per minute of the pump: GPM (10 - 45 Spm) <br />2. If pumping to a pressurized distribution system: 15.0 GPM <br />3. Enter pump description: <br />HEAD REQUIREMENTS <br />A. Elevation Difference ft <br />between pump and point of discharge: <br />B. Distribution Head Loss: ft <br />C. Additional Head Loss: ft (due to special equipment. etc.) <br />Distribution Head Loss <br />Gravity Distribution = Oft <br />Pressure Distribution based on. Minimum Average Head <br />Value on Pressure Distribution Worksheet: <br />Minimum Average Head Distribution Head Loss <br />1ft 5ft <br />2ft 6ft <br />5ft 1 Oft <br />D. 1. Supply Pipe Diameter: 1.5 in <br />2. Supply Pipe Length: 30 ft <br />E. Friction Loss in Plastic Pipe per 100ft from Table I: <br />Friction Loss = 2.67 ft per 100ft of pipe <br />F. Determine Equivalent Pipe Length from pump discharge to soil dispersal area discharge <br />point. Estimate by adding 25% to supply pipe length for fitting loss. Supply Pipe Length <br />(D.2) X 1.25 = Equivalent Pipe Length <br />Elevation <br />Of -- <br />r------------------------------------------- <br />Table I.Friction Loss in Plastic Pipe per 100ft <br />Flow Rate <br />(GPM) <br />pi a Diameter (inches) <br />1 <br />1 1.25_ <br />1.5 <br />2 <br />10 <br />9.1 <br />3.1 <br />1.3 <br />0.3 <br />12 <br />12.8 <br />4.3 <br />1.8 <br />0.4 <br />14 <br />17.0 <br />5.7 <br />2.4 <br />0.6 <br />16 <br />21.8 <br />7.3 <br />3.0 <br />0.7 <br />18 <br />9.1 <br />3.8 <br />0.9 <br />20 <br />11.1 <br />4.6 <br />1.1 <br />25 <br />16.8 <br />6.9 <br />1.7 <br />30 <br />23.5 <br />9.7 <br />2.4 <br />35 <br />12.9 <br />3.2 <br />40 <br />16.5 <br />4.1 <br />45 <br />20.5 <br />5.0 <br />50 <br />6.1 <br />55 <br />7.3 <br />60 <br />8.6 <br />65 <br />10.0 <br />70 <br />11.4 <br />75 <br />13.0 <br />85 16.4 <br />30 ft X 1.25 - 37.5 ft 95 1 1 1 1 20.1 <br />G. Calculate Supply Friction Loss by multiplying Friction Loss Per 100ft (Line E) by the Equivalent Pipe Length (Line F) and divide by 100. <br />Supply Friction Loss = <br />2.67 7 ft per 100ft X 37.5 7ft 100 = 1.0 ft <br />H• Total Head requirement is the sum of the Elevation Difference (Line A), the Distribution Head Loss (Line B), Additional Head Loss (Line C), and the <br />Supply Friction Loss (Line G ) <br />6.0 ft 5.0 it + E:::�ft + 1.0 ft = 12.0 ft <br />3. PUMP SELECTION <br />A pump must be selected to deliver at least 15.0 GPM (Line 1 or Line 2) with at least 12,0 feet of total head. <br />
The URL can be used to link to this page
Your browser does not support the video tag.