INSPECTOR CHECKLIST - mound <br />4J5U Lakeview Court <br />11 ILL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes Et bounds: out of road easement, or outer ditch. <br />LAKE / BLUFF setback: 20' for bluff. Lakes: GD -RD—, NE Protected wetland _. <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure se 10' to bed, tank Et sewer line. (else sewer line > 12" below) <br />❑ Sewer line Et baffle connection (no 90's, 3' between 45's, slope min 1" in 8', max 2" in 8') <br />(no depth req's, clean out every 100', Sch 40 pipe) <br />❑ Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />mfg 2250 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter Et alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />mfg 1250 gallons <br />9 <br />dose pump 36 gpm 27 head VERIFY PUMP CURVE 5.9 min ON 9 hr OFF <br />float setting drop 8.4 inches at 25.5 gpi "DESIGNED" 5.2 inches approx float tether length <br />213.0 gat dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 63.0 <br />Sand lift depth 22 inches. (Jar test : 2" sand leaves < 1 /8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope <br />Bermed topsoil beyond rockbed 10 upslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe Et fittings) <br />3.0 ft lateral spacing <br />7/32 inch perforations <br />3.0 ft perforation spacing <br />17.0 downslope <br />15 sideslope 24 downslope <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary <br />monitoring plan and type <br />welt abandonment form - if necessary <br />=Re -use existing tank certification <br />