My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-20-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Court
>
4350 Lakeview Court - 06-117-23-43-0019
>
Septic
>
06-20-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:29:09 PM
Creation date
9/29/2021 8:39:50 AM
Metadata
Fields
Template:
x Address Old
House Number
4350
Street Name
Lakeview
Street Type
Court
Address
4350 Lakeview Ct
Document Type
Septic
PIN
0611723430019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />DU70 rdrwger rank.. worn muurpre wrnpi rdnres <br />1250 gallon Dose tank (minimum) at 25.49 gpi <br />3GPM 27 ft. of head, Pump required <br />6 <br />8.4 1 inch swing on Demand float which translates to roughly 5.2 inches of float tether length <br />if time dosing is required - ?5.9 minutes ON time Ithours OFF time <br />20 inches from bottom of tank to "pump ON" float, or12 inches to "timer ON" float <br />23 linches from bottom of tank to "Hi Level Alarm" or 1 33 linches to "Hi level alarm" if time dosed <br />145 ft. of =inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />22 inch, or 1.8 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 61.0 ft. long 3.0 ft, lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter a alarm <br />3 clean out Et valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 10 ft. upslope berm <br />HildownsLope <br />sideslope 15 ft. sideslope berms <br />L24 jft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />berm 10 .IT 1� V Downslope bene 24 <br />12" cover on sides <br />(6" loaray cap & 6" topsoil) <br />1.8 I I Clean sand lift <br />_ 1.2 Depth to Limiting <br />L <br />InIng Condition i ------------ <br />Absorption Width 27.0 ---- ---ti-- ---- -- — <br />Note: _ <br />For 0 to 1 slopes, Absorption Width is measured from the Bedequally in .both directions. <br />For slopes a1%, Absorption Width is measured downhill from the upslope edge of the &-d. <br />Rock Bed: 21.0 yd or *1.4= 29 ton 6 inches under pipe <br />Mound Sand: 278 yd or *1.4= 390 ton calculation based on 3:1/4:1 slope from top of rackbe. <br />Loamy Cap: 80 yd3 or *1.4= 112 ton 6" deep <br />Topsoil: 91 yd or *1,4= 127 ton 6" deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).