My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-12-2017 Septic Design
Orono
>
Property Files
>
Street Address
>
P
>
Pine View Dr
>
1150 Pine View Dr - 28-118-23-42-0009
>
Septic
>
10-12-2017 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:39 PM
Creation date
9/29/2021 8:25:00 AM
Metadata
Fields
Template:
Address
House Number
1150
Street Name
Pine View
Street Type
Drive
Address
1150 Pine View Dr
Document Type
Septic
PIN
2811823420012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />:)u�b Larger rank cairn rnuiupEe comprranK5 <br />1300 Igalton Dose tank (minimum) at 25.49 gpi <br />36 GPM 25 ft, of head, Pump required <br />8.3 inch swing on Demand float which translates to roughly 5.2 inches of float tether length <br />if time dosing is required -->5.9 minutes ON time Et =hours OFF time <br />20 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />23 linches from bottom of tank to "Hi Level Alarm" or 1 33 linches to "Hi level alarm" if time dosed <br />140 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />1$ inch, or 1.5 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 61.0 ft. long =ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />FNo Effluent filter Et alarm <br />3 IcLean out Et valve box assemblies <br />20.0 Tt-Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />10.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 12 ft. upslope berm <br />3:1sideslope 11 ft. sideslope berms <br />4:1 downslope 1 17 Ift. downslope berm <br />4" inspection pipe <br />18"' cover on top <br />Upslope berm 1z <br />lam_ DownsCope berm 17 <br />12" cover on sides <br />(6" loamy cap fir 6" topsoil) <br />1.5 11 Clean sand lift <br />_ 1.5 Depth to Limiting <br />! iml ing Conditio - _ - _ __ _ - <br />Absorption Width = ----�-�- _ <br />Note: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bod <br />Rock Bed: 21.0 yd or *1.4= 29 ton 6 inches under pipe <br />Mound Sand: 156 yda or *1.4= 218 ton calculation based on 3:114:1 slope from top of rockbe, <br />Loamy Cap: 63 yd3 or *1.4= 88 ton 6" deep <br />Topsoil: 74 yd or *1.4= 104 ton 6" deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.