My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-12-2017 Septic Design
Orono
>
Property Files
>
Street Address
>
P
>
Pine View Dr
>
1150 Pine View Dr - 28-118-23-42-0009
>
Septic
>
10-12-2017 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:39 PM
Creation date
9/29/2021 8:25:00 AM
Metadata
Fields
Template:
Address
House Number
1150
Street Name
Pine View
Street Type
Drive
Address
1150 Pine View Dr
Document Type
Septic
PIN
2811823420012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design VV U 1 �I 1 yywnN.$eptiCRP.RnumP rnm lvore i S 91 <br />Property Owner: Stonewood LLC Date: 10/11/2017 <br />Site Address: 1150 Pineview Drive PID: 2811823420009 <br />Comments: <br />instructions: = = enter data = adjust if desired = computer calculated - DO NOT CHANGE! <br />1) =bedroorn Type Residential System <br />2) 750 GPD design flaw <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />s)i.2 GPD/ftz mound sand loading rate contour loading rate of =req's a min 62.5 ft. long rockbed <br />6) 10.0 ft rockbed width 63.0 ft rockbed length <br />7) =ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />s)Late rals 61.0 feet long 21.0 perfs / lateral F 63 1 perfs total <br />(1 /2 a perf means the first perf starts at the middle feed manifold) <br />9) 7/32 inch perfs at =feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size €t spacing, 0 pipe size on line 12, max perfs/lateral = 30 line #8 must be less > OK <br />10) 4.0 doses per day (4 minimum) <br />11) 188 gallons per dose (treatment volume) <br />2.00 5x <br />12) 2.00 inch diameter laterals must be used to meet 'Ax pipe volume" requirement <br />2.00 3x <br />13) F 140 feet of 2.0 inch supply line leads to DKIgations of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 212 gallons TOTAL pump out volume (treatment + drainback) <br />ls) P36 <br />]GPM <br />feet vertical lift from pump to mound laterals, leads to a: <br />16) @ =feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 750 gal Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25.49 gpi <br />Leads to a <br />18) =inch swing on Demand float, or timed dosing of5.9 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design ftow) 19hrs OFF test and adjust as necessary) <br />1')) 12 inches from bottom of tank to "Pump OFF" float <br />20) 20 inches from bottom of tank to "Pump ON" float, orP33 <br />inches to "Timer ON" float if time dosed <br />21) 23 inches from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed <br />22)714 gallons reserve capacity (after High Leve( Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.