10/07/2018 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Court
>
4330 Lakeview Court - 06-117-23-43-0017
>
Septic
>
10/07/2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:29:06 PM
Creation date
9/28/2021 3:47:57 PM
Metadata
Fields
Template:
x Address Old
House Number
4330
Street Name
Lakeview
Street Type
Court
Address
4330 Lakeview Ct
Document Type
Septic
PIN
0611723430017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
mfg 1000 gallons <br />dose pump 22 gpm 23 head VERIFY PUMP CURVE 5.7 min ON 9 hr OFF <br />float setting drop 5.0 inches at 25.o gpi "DESIGNED" 3.5 inches approx float tether length <br />125.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 38.0 <br />Sand lift depth 24 inches. (Jar test : 2" sand leaves < 1/8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upstope 17.0 downslope <br />Bermed topsoil beyond rockbed 11 upstope 20 sideslope 23 downslope <br />cover depth of 12.18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe rt fittings) <br />3.0 ft lateral spacing <br />B 7132 inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary =Re -use existing tank certification <br />monitoring plan and type <br />well abandonment form - if necessary <br />c <br />0 <br />`-r <br />d) <br />U <br />a a <br />a a <br />Z9 s <br />7S <br />b O <br />U) <br />0 0 <br />3 <br />V <br />r <br />O <br />f0 <br />Q <br />OA U) <br />c <br />0 <br />`-r <br />d) <br />U <br />
The URL can be used to link to this page
Your browser does not support the video tag.