My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10/07/2018 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Court
>
4330 Lakeview Court - 06-117-23-43-0017
>
Septic
>
10/07/2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:29:06 PM
Creation date
9/28/2021 3:47:57 PM
Metadata
Fields
Template:
x Address Old
House Number
4330
Street Name
Lakeview
Street Type
Court
Address
4330 Lakeview Ct
Document Type
Septic
PIN
0611723430017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br />inc,or2.0 ft. Sand Lift Mound <br />ft. wide by 38.0 ft. long Rock bedlaterals 2.00 inch diameter 36.0 ft. long3.0 ft. lateral spacing <br />inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 clean out li valve box assemblies <br />27.0 Ift.TotaL sand ABSORPTION width (minimum) <br />OA ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17,0 ft. Downslope (sand beyond rockbed. rninimuml <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio91ft. <br />ft. upslope berm <br />4:1 sideslope ft. sideslope berms <br />3:1 downslope downslope berm <br />4" inspection pipe <br />18" cover on top <br />Upslope berm = sl 1� t, Downslope berm 23 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />2.0 I I Clean sand lift <br />__ _ 1.0 Depth to Limiting <br />Limiting Condition -- <br />Absorption Width <br />Note: <br />For D to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 13.0 yd or "1.4= 18 ton 6 inches under pipe <br />Mound Sand: 232 yd or `1.4= 325 ton calculation based on 3:1/4:1 slope from top of rockbet <br />Loamy Cap: 66 yd3 or "1.4= 92 ton 6" deep <br />Topsoil: 77 yd or *1.4= 108 ton 6" deep <br />INSPECTOR CHECKLIST - mound <br />4.i3U LaKevrew Court <br />WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPER'T'Y LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes & bounds: out of road easement, or outer ditch. <br />LAKE / BLUFF setback: 20' for bluff. Lakes: GD _, RD _, NE _. Protected wetland �. <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure se 10' to bed,tank 8 sewer line. (else sewer line > 12" below) <br />DSewer line It baffle connection (no 90's, 3' between 45's, slope min 1" in 8', max 2" in 8') <br />(no depth reqs, clean out every 109, Sch 40 pipe) <br />Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />mfg„_,_, 2000 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter fx alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />